This code indicates overvoltage, which can be caused by main circuit DC voltage too high, using a servo drive on AC220V (AC380V) with DC bus voltage detected above 420V (760V), supply voltage exceeding input voltage range, or power supply being unstable or affected by lightning. The manual's first action is: “Measure the supply voltage”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Overvoltage (Er.400)
- Type
- Fault code
- Source
- Manual p. 185
What Er.400 means
Overvoltage p. 189
Common causes
- Main circuit DC voltage too high p. 189
- Using a servo drive on AC220V (AC380V), DC bus voltage detected above 420V (760V); or supply voltage exceeds input voltage range; p. 189
- Power supply is unstable or affected by lightning p. 189
- Acceleration/deceleration performed under relatively high voltage p. 189
- Bus voltage sampling value has large deviation p. 189
- Servo drive fault p. 189
What to do
- Measure the supply voltage p. 189
- Confirm the supply voltage and the operating speed, torque/force p. 189
- Confirm the sampled value matches the actual value p. 189
- - p. 189
Before you service the product, read the safety instructions in the manual p. 186.
If Er.400 is still not resolved
This page summarises what the manufacturer’s manual says about Er.400; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.