Inovance ISMH/ISMV series Error Er.400: Overvoltage

Servo motor · taken from the manufacturer’s manual, pages cited

Fault codeEr.400

This code indicates overvoltage, which can be caused by main circuit DC voltage too high, using a servo drive on AC220V (AC380V) with DC bus voltage detected above 420V (760V), supply voltage exceeding input voltage range, or power supply being unstable or affected by lightning. The manual's first action is: “Measure the supply voltage”

Model
Inovance ISMH/ISMV series
Display shows
Overvoltage (Er.400)
Type
Fault code
Source
Manual p. 185

What Er.400 means

Overvoltage p. 189

Common causes

  • Main circuit DC voltage too high p. 189
  • Using a servo drive on AC220V (AC380V), DC bus voltage detected above 420V (760V); or supply voltage exceeds input voltage range; p. 189
  • Power supply is unstable or affected by lightning p. 189
  • Acceleration/deceleration performed under relatively high voltage p. 189
  • Bus voltage sampling value has large deviation p. 189
  • Servo drive fault p. 189

What to do

  1. Measure the supply voltage p. 189
  2. Confirm the supply voltage and the operating speed, torque/force p. 189
  3. Confirm the sampled value matches the actual value p. 189
  4. - p. 189

Before you service the product, read the safety instructions in the manual p. 186.

If Er.400 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.400; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.