Inovance ISMH/ISMV series Error Er.832: AD Sampling Fault 2

Servo motor · taken from the manufacturer’s manual, pages cited

Fault codeEr.832

AD Sampling Fault 2 means AD conversion fault or AD unit data abnormal; driver signal cable loosened when replacing control board. The manual's first action is: “AD module fault or servo drive fault; check driver signal cable; power cycle; if the problem persists after multiple power cycles, replace the drive or seek technical support or re‑secure the cable.”

Model
Inovance ISMH/ISMV series
Display shows
AD Sampling Fault 2 (Er.832)
Type
Fault code
Source
Manual p. 185

What Er.832 means

AD Sampling Fault 2 p. 191

Common causes

  • AD conversion fault p. 191
  • AD unit data abnormal; driver signal cable loosened when replacing control board; p. 191

What to do

  1. AD module fault or servo drive fault; check driver signal cable; power cycle; if the problem persists after multiple power cycles, replace the drive or seek technical support or re‑secure the cable. p. 191

Before you service the product, read the safety instructions in the manual p. 186.

If Er.832 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.832; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.