Inovance ISMH/ISMV series Error Er.610: Drive overload

Servo motor · taken from the manufacturer’s manual, pages cited

Error codeEr.610

Drive overload means loaded operation exceeds the overload time set by the drive's inverse time curve or the UVW output may be missing a phase or have incorrect phase order. The manual's first action is: “Confirm the overload characteristics of the motor or drive and the operating command. Reassess load conditions, operating conditions, and motor capacity.”

Model
Inovance ISMH/ISMV series
Display shows
Drive overload (Er.610)
Type
Error code
Source
Manual p. 185

What Er.610 means

Drive overload p. 190

Common causes

  • Loaded operation exceeds the overload time set by the drive's inverse time curve; UVW output may be missing a phase or have incorrect phase order. p. 190
  • Motor (or drive) operation exceeds overload protection characteristics p. 190

What to do

  1. Confirm the overload characteristics of the motor or drive and the operating command. Reassess load conditions, operating conditions, and motor capacity. p. 190

Before you service the product, read the safety instructions in the manual p. 186.

If Er.610 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about Er.610; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.