This code indicates drive overcurrent 2, which can be caused by servo motor power cable wiring phase order error, missing phase, power cable ground short circuit, hardware detecting power transistor overcurrent, encoder wiring error or encoder damage, internal short circuit or ground fault in the servo drive, or internal short circuit or ground fault in the servo motor. The manual's first action is: “Confirm whether UVW phases of the servo motor connector and UVW to ground are shorted, see "Main circuit wiring"”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Drive overcurrent 2 (Er.201)
- Type
- Fault code
- Source
- Manual p. 185
What Er.201 means
Drive overcurrent 2 p. 189
Common causes
- Servo motor power cable wiring phase order error, missing phase, power cable ground short circuit, etc.; hardware detects power transistor overcurrent; encoder wiring error or encoder damage; hardware detects harmonic tube overcurrent. p. 189
- Internal short circuit or ground fault in the servo drive p. 189
- Internal short circuit or ground fault in the servo motor p. 189
- Possible encoder wiring aging/corrosion; encoder connector loose; drive signal line loose; p. 189
- Function code H0a-04 set too low p. 189
- External regeneration dump resistor too small or shorted p. 189
- Servo motor short circuit; p. 189
- Servo motor power cable UVW ground short circuit p. 189
What to do
- Confirm whether UVW phases of the servo motor connector and UVW to ground are shorted, see "Main circuit wiring" p. 189
- Confirm whether UVW phases between motor terminals and UVW to ground are shorted, see "Main circuit wiring" p. 189
- Confirm reliability of encoder wiring; confirm reliability of drive signal lines; p. 189
- Confirm H0a-04 value p. 189
- Measure the regeneration dump resistor value p. 189
- Measure whether the servo motor power cable UVW is shorted to ground. p. 189
Before you service the product, read the safety instructions in the manual p. 186.
If Er.201 is still not resolved
This page summarises what the manufacturer’s manual says about Er.201; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.