Absolute Encoder Angle Initialization Warning means encoder angle re‑initialization deviation exceeds 7.2° electrical angle or the motor shaft is mechanically locked or load torque is excessive. The manual's first action is: “Perform another angle initialization; the warning will clear”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Absolute Encoder Angle Initialization Warning (Er.960)
- Type
- Warning code
- Source
- Manual p. 186
What Er.960 means
Absolute Encoder Angle Initialization Warning p. 192
Common causes
- Warning: encoder angle re‑initialization deviation exceeds 7.2° electrical angle p. 192
- First‑time initialization of this serial motor with our drive p. 192
- Motor shaft is mechanically locked or load torque is excessive p. 192
- Motor encoder or servo drive fault p. 192
What to do
- Perform another angle initialization; the warning will clear p. 192
- Inspect the mechanical connection of the motor to external equipment p. 192
- If the warning persists after eliminating the above causes, contact the manufacturer to replace the servo motor or servo drive p. 192
Before you service the product, read the safety instructions in the manual p. 186.
If Er.960 is still not resolved
This page summarises what the manufacturer’s manual says about Er.960; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.