This code indicates drive overcurrent 1, which can be caused by servo motor power cable wiring phase order error, missing phase, power cable ground short circuit, software detecting power transistor overcurrent, encoder abnormality, main circuit cable or motor main circuit cable wiring error, poor contact, or internal short circuit in main circuit cable or motor main circuit cable. The manual's first action is: “Confirm wiring is correct, see "Main circuit wiring"”
- Model
- Inovance ISMH/ISMV series
- Display shows
- Drive overcurrent 1 (Er.200)
- Type
- Fault code
- Source
- Manual p. 185
What Er.200 means
Drive overcurrent 1 p. 189
Common causes
- Servo motor power cable wiring phase order error, missing phase, power cable ground short circuit, etc.; software detects power transistor overcurrent; encoder abnormal. p. 189
- Main circuit cable or motor main circuit cable wiring error, or poor contact p. 189
- Internal short circuit in main circuit cable or motor main circuit cable, or a ground short circuit p. 189
- Internal short circuit or ground fault in the servo drive p. 189
- Internal short circuit or ground fault in the servo motor p. 189
- Possible encoder wiring aging/corrosion; encoder connector loose; drive signal line loose; p. 189
- Function code H0a-04 set too low p. 189
- External regeneration dump resistor too small or shorted p. 189
- Servo motor short circuit; p. 189
- Servo motor power cable UVW ground short circuit p. 189
What to do
- Confirm wiring is correct, see "Main circuit wiring" p. 189
- Confirm whether UVW phases of the cable and UVW to ground have shorted, see "Main circuit wiring" p. 189
- Confirm whether the servo motor connector terminals' UVW phases and UVW to ground are shorted, see "Main circuit wiring" p. 189
- Confirm whether UVW phases between motor terminals and UVW to ground are shorted, see "Main circuit wiring" p. 189
- Confirm reliability of encoder wiring; confirm reliability of drive signal lines; p. 189
- Confirm H0a-04 value p. 189
- Measure the regeneration dump resistor value p. 189
- Measure whether the servo motor power cable UVW is shorted to ground. p. 189
Before you service the product, read the safety instructions in the manual p. 186.
If Er.200 is still not resolved
This page summarises what the manufacturer’s manual says about Er.200; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.
