ER.234 means using a servo drive on AC 220V (or AC 380V), the DC bus voltage was detected above 420V (760V) or the supply voltage exceeds the input voltage range, or the power supply is unstable or has been affected by lightning, or acceleration/deceleration was performed while the voltage was relatively high. The manual's first action is: “Measure the supply voltage”
- Model
- Inovance ISMH/ISMV series
- Display shows
- ER.234
- Type
- Fault code
- Source
- Manual p. 189
What ER.234 means
Using a servo drive on AC 220V (or AC 380V), the DC bus voltage was detected above 420V (760V) or the supply voltage exceeds the input voltage range p. 189
Common causes
- Using a servo drive on AC 220V (or AC 380V), the DC bus voltage was detected above 420V (760V) or the supply voltage exceeds the input voltage range p. 189
- Power supply is unstable or has been affected by lightning p. 189
- Acceleration/deceleration was performed while the voltage was relatively high p. 189
- DC bus voltage sampling value has a large deviation p. 189
- Servo drive fault p. 189
What to do
- Measure the supply voltage p. 189
- Confirm the supply voltage and the operating speed, torque/force p. 189
- Verify that the sampled value matches the actual value p. 189
- - p. 189
Before you service the product, read the safety instructions in the manual p. 186.
If ER.234 is still not resolved
This page summarises what the manufacturer’s manual says about ER.234; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.