Inovance ISMH/ISMV series Error ER.234

Servo motor · taken from the manufacturer’s manual, pages cited

Fault codeER.234

ER.234 means using a servo drive on AC 220V (or AC 380V), the DC bus voltage was detected above 420V (760V) or the supply voltage exceeds the input voltage range, or the power supply is unstable or has been affected by lightning, or acceleration/deceleration was performed while the voltage was relatively high. The manual's first action is: “Measure the supply voltage”

Model
Inovance ISMH/ISMV series
Display shows
ER.234
Type
Fault code
Source
Manual p. 189

What ER.234 means

Using a servo drive on AC 220V (or AC 380V), the DC bus voltage was detected above 420V (760V) or the supply voltage exceeds the input voltage range p. 189

Common causes

  • Using a servo drive on AC 220V (or AC 380V), the DC bus voltage was detected above 420V (760V) or the supply voltage exceeds the input voltage range p. 189
  • Power supply is unstable or has been affected by lightning p. 189
  • Acceleration/deceleration was performed while the voltage was relatively high p. 189
  • DC bus voltage sampling value has a large deviation p. 189
  • Servo drive fault p. 189

What to do

  1. Measure the supply voltage p. 189
  2. Confirm the supply voltage and the operating speed, torque/force p. 189
  3. Verify that the sampled value matches the actual value p. 189
  4. - p. 189

Before you service the product, read the safety instructions in the manual p. 186.

If ER.234 is still not resolved

  • 请按本手册记载的步骤-指示进行试运行 p. 2
    “请按本手册记载的步骤-指示进行试运行”
  • 请采取措施以确保再起动时不会危及到人身安全 p. 2
    “请采取措施以确保再起动时不会危及到人身安全”

This page summarises what the manufacturer’s manual says about ER.234; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.