Fault codeEr.101
This code indicates EEPROM parameter abnormality, which can be caused by abnormal servo internal parameters, sudden drop of control power supply voltage, or power being cut off during parameter write. The manual's first action is: “NO.1”
- Model
- Inovance ISMH/ISMV series
- Display shows
- EEPROM parameter abnormality (Er.101)
- Type
- Fault code
- Source
- Manual p. 184
What Er.101 means
EEPROM parameter abnormality p. 184
Common causes
- Abnormal servo internal parameters p. 184
- 1. Sudden drop of control power supply voltage p. 184
- 2. Power was cut off during parameter write p. 184
- 3. Number of parameter writes within a certain time exceeded the maximum p. 184
- 4. False operation caused by noise from AC power, grounding, or static electricity p. 184
- 5. Failure of internal components of the servo drive caused by gas, water droplets, or cutting oil p. 184
- 6. Servo drive failure p. 184
What to do
- NO.1 p. 184
- Measure the power supply voltage p. 184
- Confirm the duration of power loss p. 184
- Confirm whether the upper-level device has frequently changed parameters. p. 184
- If the fault persists after multiple power cycles, it may be that the servo drive has failed. p. 184
- It may be a servo drive fault; repair or replace the servo drive. Change the parameter write method. p. 184
- It may be a servo drive fault; repair or replace the servo drive. p. 184
Before you service the product, read the safety instructions in the manual p. 186.
If Er.101 is still not resolved
This page summarises what the manufacturer’s manual says about Er.101; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Inovance. Found a mistake? Report an error.