Key facts
Start here

Vaisala HM44 Humidity Measurement Kit User Manual
This manual describes the Vaisala HM44 humidity measurement kit, including the HMP44 probe, HMI41 indicator, accessories and the required installation steps. It guides users through setting up the indicator, configuring measurement parameters, and performing moisture measurements in concrete or other building structures.
The document also covers calibration procedures, battery status monitoring, troubleshooting, spare parts, and technical specifications such as dimensions, probe count, and accuracy. All instructions are provided in Swedish and reference the English version for clarification. This manual is written in Swedish.
Vaisala HM44 specifications
| Probe model | HMP44 humidity and temperature probe |
|---|---|
| Indicator model | HMI41 indicator |
| Rubber plugs included | 12 pcs |
| Plastic sleeves included | 12 pcs |
Source: Vaisala HM44 User Guide
All Vaisala HM44 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How do you activate the setup mode on the HMI41 display?
Press the ON/OFF button until the word SETUP appears, then repeatedly press ENTER and MODE until the display shows SETUP.
How many probes can be connected to the HMI41 indicator?
Up to ten probes can be connected, numbered 1 through 10.
How many sensors can be connected to one HMI41 unit?
Up to ten sensors can be connected, each assigned a number from 1 to 10.
From: Vaisala HM44 User Manual