Siemens SINAMICS V80 Manuals

ManualLib has 3 documents for the Siemens SINAMICS V80 (Automation control Equipment): 1 user manual, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

User Manual 1Product Leaflet 1

Key facts

Brand
Siemens
Model
SINAMICS V80
Documents
3
Languages
ZH
Last added
2023-10-31

Start here

Siemens SINAMICS V80 Servo Drive Operation Manual

Siemens SINAMICS V80 Servo Drive Operation Manual

User Manual 66 pages · 3.8 MB · ZH

This is the operation manual for the Siemens SINAMICS V80 small servo drive, dated 04.2008. It begins with safety precautions and then covers system preparation, installation, system wiring, trial operation, fault display and handling, system maintenance and service, and specifications.

The manual gives installation environment limits of 0 to +55 °C, 90% RH or less, altitude up to 1000 m, vibration resistance 4.9 m/s² and shock resistance 19.6 m/s². Wiring notes specify a single-phase 200–230 V supply, at least 300 mm separation between power and signal lines, I/O signal cables up to 3 m, encoder cables up to 20 m, and a wait of 5 minutes after the PWR LED goes out before touching terminals. Recommended power filters include Schaffner FN2070 models. This manual is written in Chinese.

Read online

Siemens SINAMICS V80 specifications

Operating ambient temperature0 °C to +55 °C
Operating ambient humidity90% RH or less (no condensation)
Storage temperature-20 °C to +70 °C
Altitude1000 m or less
Vibration resistance4.9 m/s²
Shock resistance19.6 m/s²
Power supplySingle-phase 200–230 V
Maximum I/O signal cable length3 m
Maximum encoder cable length20 m
GroundingD-type grounding (100 Ω or less)

Source: Siemens SINAMICS V80 Servo Drive Operation Manual

All Siemens SINAMICS V80 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What supply voltage does the SINAMICS V80 use?

It uses a single-phase 200–230 V supply.

From: Siemens SINAMICS V80 Servo Drive Operation Manual

How long must I wait after turning off power before touching the terminals?

Wait at least 5 minutes after the power LED (PWR) goes out; residual high voltage may remain inside the drive.

From: Siemens SINAMICS V80 Servo Drive Operation Manual

What is the supply voltage range for the SINAMICS V80?

The driver operates from 200 V to 230 V AC at 50/60 Hz.

From: Siemens SINAMICS V80 Servo Driver Product Sample

What power range does the SINAMICS V80 support?

It is rated for 100 W up to 750 W.

From: Siemens SINAMICS V80 Servo Driver Product Sample