Siemens SINAMICS V80 Servo Drive Operation Manual

This is a manual of SINAMICS V80 servo drive, which mainly introduces safety precautions, system preparation, installation, system wiring, trial run, fault display and handling, system maintenance and service, specifications and instructions.


Siemens SINAMICS V80 Servo Drive Operation Manual - cover page
Brand
Siemens
Category
Automation control Equipment
Document type
User Manual
Language
Chinese
Pages
66
File format
PDF
File size
3.8 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
5C319A4D596EDC4C60F7801D056C65E6

About this manual

This is the operation manual for the Siemens SINAMICS V80 small servo drive, dated 04.2008. It begins with safety precautions and then covers system preparation, installation, system wiring, trial operation, fault display and handling, system maintenance and service, and specifications.

The manual gives installation environment limits of 0 to +55 °C, 90% RH or less, altitude up to 1000 m, vibration resistance 4.9 m/s² and shock resistance 19.6 m/s². Wiring notes specify a single-phase 200–230 V supply, at least 300 mm separation between power and signal lines, I/O signal cables up to 3 m, encoder cables up to 20 m, and a wait of 5 minutes after the PWR LED goes out before touching terminals. Recommended power filters include Schaffner FN2070 models. This manual is written in Chinese.

What's inside

  • Safety precautions
  • System preparation
  • Installation
  • System wiring
  • Trial operation
  • Fault display and handling
  • System maintenance and service
  • Specifications and descriptions

Specifications

Operating ambient temperature0 °C to +55 °C
Operating ambient humidity90% RH or less (no condensation)
Storage temperature-20 °C to +70 °C
Altitude1000 m or less
Vibration resistance4.9 m/s²
Shock resistance19.6 m/s²
Power supplySingle-phase 200–230 V
Maximum I/O signal cable length3 m
Maximum encoder cable length20 m
GroundingD-type grounding (100 Ω or less)

Frequently asked questions

What supply voltage does the SINAMICS V80 use?

It uses a single-phase 200–230 V supply.

How long must I wait after turning off power before touching the terminals?

Wait at least 5 minutes after the power LED (PWR) goes out; residual high voltage may remain inside the drive.

What are the maximum cable lengths for I/O signals and the encoder?

The I/O signal cable can be up to 3 m and the encoder cable up to 20 m.

Can three-phase power be connected to the U, V and W output terminals?

No. The manual prohibits connecting a three-phase power supply to the U, V and W output terminals.

Download PDF (3.8 MB)

More Siemens Manuals