Ningbo Anson Hi Series Error Codes

56 codes from pages 85–88 of the manual

This is the list of error codes the Ningbo Anson manual gives for the Hi Series servo drive. Find your code below and open it for what the manual says about its causes and what to do.

Error codes from p. 85

CodeWhat it meansPage
Er049 Software overvoltage p. 85
Er055 Hardware overvoltage p. 85
Er050 Software overcurrent p. 85
Er056 Hardware overcurrent p. 85
Er051 IGBT shortcircuit p. 85
Er053 Software undervoltage p. 85
Er054 Over-heated Heatsink p. 85
Er071 Pressure sensor disconnection p. 86
Er081 Key operation error p. 86
Er084 Non-finished self-searching notch position p. 86
Er122 Error setting of motor model DR.01 p. 86
Er129 CAN bus communication is wrong. p. 86
Er033 Power board fails. p. 86
Er048 CD.00 (DC link controller setting value is wrong.) p. 86
Er052 NTC's temperature anomaly p. 86
Ei053 Software undervoltage p. 87
Ei054 Over-heated Heatsink p. 87
Ei055 Hardware overvoltage p. 87
Ei056 Hardware overcurrent p. 87
Ei057 Self-checking circuit error of sampling Phase-U current p. 87
Ei058 Input voltage too high p. 87
Ei059 Power-on self test fails p. 87
Ei060 The setting of PU.02 is wrong. p. 87
Ei061 Self-checking circuit error of sampling Phase-V current p. 87
Ei062 Self-checking circuit error of sampling Phase-W current p. 87
Ei063 Heatsink's temperature is too low. p. 87
Ei066 Over-heated Motor p. 87
Ei067 Over-loaded Motor p. 87
Ei068 Searching initial angle fails p. 87
Ei069 Reverse overspeed of Motor p. 87
Ei070 Zero sequence current exceeds the threshold value p. 87
Ei071 Pressure sensor disconnection p. 87
Ei073 Z pulse searching failure p. 87
Ei074 Incompletion of Z pulse searching p. 87
Ei080 Digital input ports' shortcut configurations are repetitive. p. 87
Ei081 Key operation error p. 87
Ei082 Abnormal FPGA communication p. 87
Ei083 Encoder error p. 87
Ei084 Non-finished self-searching notch position p. 87
Ei085 The encoder initialization fails. p. 87
Ei086 External error happens. p. 87
Ei07 Emulation encoder error p. 88
Ei08 Encoder 2 error p. 88
Ei097 Timeout of EEPROM p. 88
Ei098 Version changes p. 88
Ei099 EEPROM is erased p. 88
Ei100 EEPROM is interrupted p. 88
Ei107 Error parameters storage p. 88
Er108 Error parameters calibration p. 88
Er112 Error setting of parameter batch p. 88
Er113 Error factory default setting p. 88
Er114 Error storage of parameter initialization p. 88
Er117 Error setting of drive model PU10 p. 88
Er131 Timeout of VARAN bus communication p. 88
Er132 Timeout of PDO watchdog's EtherCAT p. 88
Er133 Timeout of CAN bus's heartbeat message p. 88

Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Ningbo Anson. Found a mistake? Report an error.