Ningbo Anson Hi Series Error Ei066: Over-heated Motor

Servo drive · taken from the manufacturer’s manual, pages cited

Error codeEi066

Motor overheated because the temperature sensor wiring is shorted, circuited, or loosened. The manual's first action is: “1.Check the temperature wirings 2.Check whether the internal motor is over heated or temperature sensor wiring is short-circuited”

Model
Ningbo Anson Hi Series
Display shows
Over-heated Motor (Ei066)
Type
Error code
Source
Manual p. 87

What Ei066 means

Over-heated Motor p. 87

Common causes

  • 1.The temperature sensor wiring is short, circuited or loosening connection. p. 87

What to do

  1. 1.Check the temperature wirings 2.Check whether the internal motor is over heated or temperature sensor wiring is short-circuited p. 87

If Ei066 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Ningbo Anson service.

This page summarises what the manufacturer’s manual says about Ei066; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Ningbo Anson. Found a mistake? Report an error.