Error codeEr049
Software overvoltage occurs when the voltage is too high, regenerated energy exceeds brake resistor consumption, or the brake resistor connection is loose or disconnected. The manual's first action is: “1.Check the A.C. voltage”
- Model
- Ningbo Anson Hi Series
- Display shows
- Software overvoltage (Er049)
- Type
- Error code
- Source
- Manual p. 85
What Er049 means
Software overvoltage p. 85
Common causes
- 1.Voltage is too high. p. 85
- 2.The regenerated energy is larger than the energy that the brake resistor consumes. p. 85
- 3.The brake resistor is loosening connection or disconnected. p. 85
- 4.Increase the speed-reducing time RF02 p. 85
- 5.Increase the release torque time CS.22 p. 85
- 6.Seek for technical support. p. 85
- 1. Voltage is too high. 2. The regenerated energy is larger than the energy that the brake resistor consumes 3. The brake resistor is loosening connection or disconnected. 4. Internal brake loop is abnormal. p. 85
What to do
- 1.Check the A.C. voltage p. 85
- 2.Reduce the brake resistance value p. 85
- 3.Increase the wiring of brake resistor p. 85
- 4.Increase the speed-reducing time RF02 p. 85
- 5.Increase the release torque time CS.22 p. 85
- 6.Seek for technical support. p. 85
- 1. Check the A.C. voltage 2. Reduce the brake resistance value 3. Check the wiring of brake resistor 4. Increase the speed-reducing time RF02 5. Increase the release torque time CS.22 6. Seek for technical support p. 85
If Er049 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Ningbo Anson service.
This page summarises what the manufacturer’s manual says about Er049; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Ningbo Anson. Found a mistake? Report an error.