Motor reverse overspeed caused by too fast torque release or large speed loop parameters. The manual's first action is: “1.Increase torque release time (CS.22) 2.Modify the setting of speed loop, decrease Kp(CS00) or increase Ti (CS.01) 3.Check recent error records, the cause of Ei069”
- Model
- Ningbo Anson Hi Series
- Display shows
- Reverse overspeed of Motor (Ei069)
- Type
- Error code
- Source
- Manual p. 87
What Ei069 means
Reverse overspeed of Motor p. 87
Common causes
- 1.Torque release is too fast, CS.22 is too small. 2.The parameters of speed loop is too large. p. 87
What to do
- 1.Increase torque release time (CS.22) 2.Modify the setting of speed loop, decrease Kp(CS00) or increase Ti (CS.01) 3.Check recent error records, the cause of Ei069 p. 87
If Ei069 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Ningbo Anson service.
This page summarises what the manufacturer’s manual says about Ei069; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Ningbo Anson. Found a mistake? Report an error.