Key facts
- Brand
- Linear Technology
- Model
- AN8
- Category
- Other Electronics
- Documents
- 10
- Languages
- EN
- Last added
- 2012-06-05
Start here

Linear Technology AN8 Power Conditioning Techniques for Batteries Application Note
The document discusses the necessity of power conditioning when applying battery voltages to circuitry, noting that standard IC regulators often consume too much quiescent current or cannot operate at low input voltages. It covers general classes of regulators including voltage inverters, step-down circuits, and step-up converters.
Read onlineLinear Technology AN8 specifications
| Noise (Typical) | 20 mVRMS |
|---|---|
| Dropout Voltage | 300mV at 100mA |
| Quiescent Current | 20 mA |
| Noise Bandwidth | 10Hz to 100kHz |
All Linear Technology AN8 documents by type
How to use the product for one specific task, with worked examples.
- Linear Technology AN8 Power Conditioning Techniques for Batteries Application Note 10 p
- Linear Technology LTC2400 Application Note AN80-1 8 p
- Linear Technology AN82-1 Voltage Reference Application Note 12 p
- Linear Technology AN83-1 Performance Verification of Low Noise, Low Dropout Regulators Application Note 20 p
- Linear Technology AN85-1 Low Noise Varactor Biasing Application Note 24 p
- Linear Technology AN86-1 Application Note: 20-Bit DAC Design 52 p
- Linear Technology AN89-1A Thermoelectric Cooler Temperature Controller Application Note 12 p
Questions answered in these manuals
What is the quiescent current of the low dropout regulator circuit in Figure 6?
The quiescent current is 760µA.
From: Linear Technology AN8 Power Conditioning Techniques for Batteries Application Note
What is the output capability of the low dropout regulator in Figure 6?
The circuit has a 100mA capacity output and includes short circuit protection.
From: Linear Technology AN8 Power Conditioning Techniques for Batteries Application Note
What is the maximum conversion rate for the LTC2400?
The maximum conversion rate for this particular part is 15Hz (with 120Hz rejection).
Is a PGA required with the LTC2400?
No, a PGA is not required with the LTC2400 because it enables direct digitizing of low level signals over a wide input range.
What accuracy range do monolithic reference initial accuracies typically cover?
Monolithic reference initial accuracy ranges from 0.02% to 1%, representing a 1LSB error in systems ranging from 6-bit to 12-bit.
From: Linear Technology AN82-1 Voltage Reference Application Note
How does the long-term stability of buried Zeners compare to bandgap references?
Buried Zeners typically perform better than 20ppm/√kh, whereas bandgaps usually fall between 20ppm and 50ppm/√kh.
From: Linear Technology AN82-1 Voltage Reference Application Note