Key facts
- Brand
- Delta
- Model
- DVP201
- Category
- Industrial Supply
- Documents
- 2
- Languages
- ZH · EN
- Last added
- 2023-11-19
Start here

Delta DVP201/202/211LC-SL Load Cell Weighing Module Operation Manual
This operation manual covers the Delta DVP201/202/211LC-SL Load Cell Weighing Module, detailing its principles, specifications, and physical appearance. It explains how to install the module on a DIN rail and connect it to load cell sensors via 4-wire or 6-wire configurations. This manual is written in Chinese.
Read onlineDelta DVP201 specifications
| Power Supply | 24 VDC (-15 ~ +20%) |
|---|---|
| Resolution | 24-bit Hardware, 32-bit Data Output |
| Maximum Accuracy | 0.04% |
| Communication Interfaces | RS-232, RS-485 |
| Suitable Sensor Forms | 4-wire or 6-wire Load Cell |
| Temperature Coefficient | ≤ ± 20 ppm/K |
| Protection Rating | IP20 |
Source: Delta DVP201/202/211LC-SL Load Cell Weighing Module Operation Manual
All Delta DVP201 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What are the supported reaction times for the module?
The module supports reaction times of 2.5, 10, 16, 20, 50, 60, 100, 200, and 400ms.
From: Delta DVP201/202/211LC-SL Load Cell Weighing Module Operation Manual
Which sensor characteristic values are supported?
The module supports characteristic values ranging from 0 to 80 mV/V.
From: Delta DVP201/202/211LC-SL Load Cell Weighing Module Operation Manual
What is the precision of the DVP201/202/211LC-SL Load Cell Module?
The precision of the load cell module is 0.04%.
From: Delta DVP201/202/211LC-SL Load Cell Module Operation Manual
Can the module support 6-wire load cells?
Yes, the module provides 24-bit resolution applicable to 4-wire or 6-wire load cells.
From: Delta DVP201/202/211LC-SL Load Cell Module Operation Manual