Key facts
- Brand
- SGS-THOMSON
- Model
- BTA06
- Industry
- Industrial
- Documents
- 4
- Languages
- EN
- Last added
- 2012-07-09
Start here

SGS-THOMSON BTA06/BTB06 TW/SW Logic Level Triacs Datasheet
This document is a datasheet for the SGS-THOMSON BTA06 TW/SW and BTB06 TW/SW logic level triacs. It provides detailed specifications including RMS on-state current, surge peak on-state current, and gate characteristics. The devices are designed for low power trigger circuits such as microcontrollers and integrated circuits.
Read onlineSGS-THOMSON BTA06 specifications
| RMS on-state current (360° conduction angle) | 6 A (BTA) / 6 A (BTB) |
|---|---|
| Non repetitive surge peak on-state current (tp = 8.3 ms) | 63 A |
| Critical rate of rise of on-state current (Repetitive) | 20 A/ µs |
| Storage and operating junction temperature range (BTA) | - 40 to + 150 °C |
| Maximum lead temperature for soldering | 260 °C |
| Junction to ambient thermal resistance | 60 °C/W |
| Junction to case thermal resistance (DC) | 4.4 °C/W (BTA) / 3.3 °C/W (BTB) |
| Gate trigger current (MAX) | 5 mA (TW) / 10 mA (SW) |
| Gate trigger voltage (MAX) | 1.5 V |
| Package type | TO220AB Plastic |
Source: SGS-THOMSON BTA06/BTB06 TW/SW Logic Level Triacs Datasheet
All SGS-THOMSON BTA06 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Questions answered in these manuals
What are the BTA06 and BTB06 TW/SW triacs adapted for?
They are adapted for low power trigger circuits such as microcontrollers, microprocessors, and integrated circuits.
From: SGS-THOMSON BTA06/BTB06 TW/SW Logic Level Triacs Datasheet
What is the maximum RMS on-state current for the BTA06 TW/SW?
The maximum RMS on-state current is 6 A at a case temperature of 80 °C.
From: SGS-THOMSON BTA06/BTB06 TW/SW Logic Level Triacs Datasheet
What is the recommended torque value for mounting?
The recommended torque value is 0.8 m.N.
Is this TRIAC suitable for light dimmer applications?
Yes, the insulated TO220AB package and high surge current make it well adapted to LIGHTDIMMER applications.
What are the applications for these triacs?
They are suitable for general purpose applications where high surge current capability is required, such as phase control and static switching on inductive or resistive loads.
What is the maximum junction temperature for operation?
The maximum operating junction temperature (Tj) for BTA devices is +150 °C.