STMicroelectronics STPM01 Power Management Device User Manual
This document is a user guide for the STPM01 Power Management Device, providing instructions on using the Graphical User Interface (GUI) to access options for settings, calibration, and measurement. It details how to interact with the device via status bits, measured information, and parameter adjustments.
Read onlineSTMicroelectronics STPM01 specifications
| Measurement Frequency Range (MDIV=0) | 4.000MHz-4.194MHz |
|---|---|
| Measurement Frequency Range (MDIV=1) | 8.000MHz-8.192MHz |
| Oscillator Selection (RC=0) | crystal oscillator |
| Oscillator Selection (RC=1) | RC oscillator |
Source: STMicroelectronics STPM01 Power Management Device User Manual
All STMicroelectronics STPM01 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
- STMicroelectronics STPM01 Programmable Single Phase Energy Metering IC Datasheet 60 p
- ST STEVAL-IHP002V2 Smartplug system to measure control AC loads based on the STM32 ST7540 PLM STPM01 handbook 10 p
- ST STEVAL-IHP001V3 ZigBee SmartPlug demonstration board based on the STM32F10x SPZB260-PRO STPM01 handbook 11 p
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What does the 'no load condition' status bit indicate?
A value of 0 means no load condition is not detected, while a value of 1 means a no load condition is detected.
From: STMicroelectronics STPM01 Power Management Device User Manual
What is the purpose of the 'TSTD' bit in the Panel Page?
The TSTD bit controls test mode and OTP write disable; setting it to 1 enables normal operation and prevents writes to OTP.
From: STMicroelectronics STPM01 Power Management Device User Manual
What sensors does the STPM01 support?
The device can be implemented using Rogowski coil, current transformer, and shunt sensors.
From: STMicroelectronics STPM01 Programmable Single Phase Energy Metering IC Datasheet
Does the STPM01 support 50 Hz and 60 Hz frequencies?
Yes, it supports both 50 + 60 Hz frequencies.
From: STMicroelectronics STPM01 Programmable Single Phase Energy Metering IC Datasheet
What is the primary function of the STEVAL-IHP002V2?
The demonstration board implements a PLM smartplug node that monitors energy consumption and controls loads in on/off mode through a relay.
What physical enclosure is the board designed to fit?
The board is designed to fit a standard "503" wall box.