This application note describes how to design a three-phase meter using the STPM01 metering device and a VIPer12A-based switch-mode power supply. The STPM01 measures active, reactive and apparent energies, Vrms, Irms, instantaneous voltage and current, and frequency in power line systems.
The reference design uses three STPM01 devices with a common clock network and a fly-back power supply based on the VIPer12A. It supports 3-wire delta, 4-wire delta and wye service, and requires a supervisory board for energy integration and data display.
| Input voltage | 80-480 Vrms |
|---|---|
| Current range | 5-30 Arms |
| Line frequency | 45-65 Hz |
| Ambient temperature | -40 to +85 °C |
| Switching frequency | 60 KHz |
Three STPM01 devices are used with a common clock network.
The VIPer12A converter switching frequency is fixed at 60 KHz.
No, the meter cannot be used in standalone mode and requires a management board.
It supports 3-wire delta, 4-wire delta and wye service.