Key facts
- Brand
- NEC
- Model
- 78K0S/K B1+
- Category
- Other device
- Industry
- Electronics
- Documents
- 3
- Languages
- ZH
- Last added
- 2000-01-01
Start here
NEC 78K0S/KB1+ PD78F9232 PD78F9234 PD78F9232(A) PD78F9234(A) PD78F9232(A2) PD78F9234(A2) 8 pin monolithic micro controller user manual
This manual provides detailed information for engineers designing with the NEC 78K0S/KB1+ microcontroller family, including the PD78F9232, PD78F9234 and their A/A2 variants. It covers pin descriptions, CPU architecture, electrical characteristics, interrupt handling, reset behavior, low‑voltage detection, option bytes, and flash programming.
The document also includes safety and handling instructions such as ESD protection, power‑on sequencing, and recommended soldering conditions, plus references to related development tools and programming guides. This manual is written in Chinese.
NEC 78K0S/K B1+ specifications
| Supported devices | 78K0/KE2, 78K0S/KA1+, 78K0S/KB1+, 78K0S/KU1+, 78K0S/KY1+ |
|---|---|
| Release date | November 2007 |
| Software version | Applilet EZ PL Ver.3.1 |
Source: NEC Applilet EZ PL Ver.3.1 78K0/KE2 78K0S/KA1+ 78K0S/KB1+ 78K0S/KU1+ 78K0S/KY1+ device user manual
All NEC 78K0S/K B1+ documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Which microcontroller families are supported by Applilet EZ PL Ver.3.1?
It supports the 78K0/KE2 and 78K0S/Kx1+ series devices.
From: NEC Applilet EZ PL Ver.3.1 78K0/KE2 78K0S/KA1+ 78K0S/KB1+ 78K0S/KU1+ 78K0S/KY1+ device user manual
What is the purpose of this manual?
The manual helps users understand the operation method and functions of Applilet EZ PL Ver.3.1 for designing applications with the listed microcontrollers.
From: NEC Applilet EZ PL Ver.3.1 78K0/KE2 78K0S/KA1+ 78K0S/KB1+ 78K0S/KU1+ 78K0S/KY1+ device user manual
What is the recommended power‑up sequence for the 78K0S/K B1+?
First turn on the internal power supply, then the external supply; for power‑down, turn off the external supply before the internal one.