Danfoss VLT® AutomationDrive FC 300 Low Harmonic Drive Operating Instructions
This document is the operating instructions for the Danfoss VLT® AutomationDrive FC 300 Low Harmonic Drive frequency converter. It explains how to read the manual, safety requirements, installation, operation using the graphical LCP, programming of the frequency converter and active filter, RS-485 installation and setup, general specifications, and troubleshooting.
The drive has two LCPs, one for the frequency converter on the right and one for the active filter on the left, and each LCP controls only the unit it is connected to. The instructions apply to units with software version 5.9x.
Danfoss VLT AutomationDrive FC 300 specifications
| Software version | 5.9x |
|---|---|
| Earth leakage current | higher than 3.5 mA |
| Motor thermal protection parameter | par. 1-90 |
| Software version parameter | par. 15-43 Software Version |
Source: Danfoss VLT® AutomationDrive FC 300 Low Harmonic Drive Operating Instructions
All Danfoss VLT AutomationDrive FC 300 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Instruction set, parameters and examples for configuring or programming the device.
Questions answered in these manuals
What software version do these operating instructions apply to?
These operating instructions can be used for all VLT Automation Low Harmonic Drive frequency converters with software version 5.9x.
From: Danfoss VLT® AutomationDrive FC 300 Low Harmonic Drive Operating Instructions
How many LCPs does the Low Harmonic Drive have?
The Low Harmonic Drive has two LCPs, one for the frequency converter to the right and one for the active filter to the left.
From: Danfoss VLT® AutomationDrive FC 300 Low Harmonic Drive Operating Instructions
Which software version does this FC 300 programming guide cover?
It can be used for all FC 300 frequency converters with software version 6.3x, which can be seen in parameter 15-43 Software Version.
How far from the drive can the Danfoss LCP be mounted?
The detachable Local Control Panel can be installed up to 3 metres from the frequency converter using the installation kit option.
What does the MCB 113 add to the FC 300?
It adds 7 digital inputs, 2 analog outputs and 4 SPDT relays to the standard I/O of the frequency converter.
From: Danfoss VLT AutomationDrive FC 300 Extended Relay Card MCB 113 Operating Instructions
How is the relay connection different?
The connection of these relays is different than for the standard relays of the FC 300. The coil is between T2 and T3 instead of between T1 and T2.
From: Danfoss VLT AutomationDrive FC 300 Extended Relay Card MCB 113 Operating Instructions