Danfoss VLT AutomationDrive FC 300 Extended Relay Card MCB 113 operating instructions for installation, setup, connections, and safety.
This manual covers the VLT Extended Relay Card MCB 113 option for the Danfoss VLT AutomationDrive FC 300. It explains how to read the instructions, including approvals, symbols, abbreviations, safety, and the introduction to the card.
The manual also describes connection schematics, installation of the option in the frequency converter, parameter set-up, digital inputs, analog outputs, external 24 V DC supply, and data readouts.
| Digital inputs, analog outputs, and SPDT relays | 7 digital inputs, 2 analog outputs and 4 SPDT relays |
|---|
It adds 7 digital inputs, 2 analog outputs and 4 SPDT relays to the standard I/O of the frequency converter.
The connection of these relays is different than for the standard relays of the FC 300. The coil is between T2 and T3 instead of between T1 and T2.
The mains supply to the frequency converter must be disconnected whenever repair work is to be carried out. Check that the mains supply has been disconnected before removing motor and mains supply plugs.