Danfoss FC 302 Manuals

ManualLib has 4 documents for the Danfoss FC 302 (inverter): 4 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 4

Key facts

Brand
Danfoss
Model
FC 302
Category
inverter
Industry
Industrial
Documents
4
Languages
ZH · EN · ES
Last added
2026-11-10

Start here

Danfoss VLT AutomationDrive FC 302 Operating Guide

Danfoss VLT AutomationDrive FC 302 Operating Guide

User Manual 160 pages · 13 MB · EN

This operating guide provides instructions for the safe installation and commissioning of the VLT AutomationDrive FC 302 variable frequency drive, covering enclosure sizes D1h through D8h. It is intended for use by qualified personnel and includes detailed safety precautions regarding high voltage, unintended motor starts, and discharge times. The manual outlines the intended use, product overview, and mechanical and electrical installation requirements.

Read online

Danfoss FC 302 specifications

Maximum output frequency (from software version 6.72)Limited to 590 Hz
Leakage currentMore than 3.5 mA
CE certification range1400–2000 kW (1875–2680 hp), 690 V
UL complianceUL 508C temperature storage requirements
Dimension drawing unitsmm (in)
Minimum discharge wait time, 525–690 V (355–2000 kW)40 minutes

Source: Danfoss VLT AutomationDrive FC 302 12-Pulse Drive Operating Manual

All Danfoss FC 302 documents by type

Questions answered in these manuals

变频器的输出频率最大限制是多少?

从软件版本 6.72 起,变频器的输出频率被限制在 590 Hz;软件版本 6x.xx 也将最大输出频率限制在 590 Hz。

From: Danfoss VLT AutomationDrive FC 302 12-Pulse Drive Operating Manual

切断电源后要等多久才能进行维护或修理作业?

按表 2.1,380–500 V(250–1000 kW)功率范围至少等待 30 分钟,525–690 V(355–2000 kW)至少等待 40 分钟。

From: Danfoss VLT AutomationDrive FC 302 12-Pulse Drive Operating Manual

Who is qualified to install or operate this drive?

Only qualified personnel are allowed to install or operate this equipment.

From: Danfoss VLT AutomationDrive FC 302 Operating Guide

What is the minimum waiting time before performing service work?

The minimum waiting time is 20 minutes to allow capacitors to discharge fully.

From: Danfoss VLT AutomationDrive FC 302 Operating Guide

What is the maximum output frequency of the FC 302 12-pulse drive?

From software version 6.72, the output frequency is limited to 590 Hz.

From: Danfoss VLT AutomationDrive FC 302 12-Pulse Drive Operating Manual

Which enclosure sizes are covered for terminal locations?

The manual locates terminals for enclosure sizes F8 through F15.

From: Danfoss VLT AutomationDrive FC 302 12-Pulse Drive Operating Manual