Key facts
- Brand
- Danfoss
- Model
- FC 301/302
- Industry
- Electronics
- Documents
- 4
- Languages
- EN · ZH
- Last added
- 2026-11-05
Start here

Danfoss VLT® AutomationDrive FC 301/302 Operating Guide
This guide provides step-by-step instructions for installing, commissioning, and operating the Danfoss VLT® AutomationDrive FC 301/302 frequency converter. It includes safety precautions, mechanical and electrical installation details, commissioning procedures, application setup examples, and troubleshooting. The guide is intended for qualified personnel and emphasizes safety throughout, including warnings for high voltage and unintended motor start. It also covers specifications, enclosure sizes, and disposal instructions.
Read onlineDanfoss FC 301/302 specifications
| Mains Supply (200–240 V) | 200–240 V |
|---|---|
| Mains Supply (380–500 V) | 380–500 V |
| Mains Supply (525–600 V) | 525–600 V (FC 302 only) |
| Mains Supply (525–690 V) | 525–690 V (FC 302 only) |
| Output Frequency Limit | 590 Hz |
Source: Danfoss VLT® AutomationDrive FC 301/302 Operating Guide
All Danfoss FC 301/302 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the maximum output frequency of the FC 301/302?
The output frequency is limited to 590 Hz. A version with 1000 Hz is available for EU export.
From: Danfoss VLT® AutomationDrive FC 301/302 Operating Guide
Who should use this operating guide?
This guide is intended for qualified personnel who are trained to install, commission, and maintain the frequency converter safely.
From: Danfoss VLT® AutomationDrive FC 301/302 Operating Guide
What is the purpose of this manual?
This manual provides information for the safe installation and commissioning of the VLT AutomationDrive FC 301/302 variable frequency drive.
From: Danfoss VLT AutomationDrive FC 301/302 Operation Manual
Who is authorized to install or operate this device?
Only qualified personnel who have been trained and are authorized by law to install, commission, and maintain the equipment may do so.
From: Danfoss VLT AutomationDrive FC 301/302 Operation Manual
What is the maximum output frequency of the frequency converter?
The output frequency is limited to 590 Hz.
From: Danfoss VLT® AutomationDrive FC 301/302 0.25–75 kW Operating Guide
What is the minimum cable cross-section required?
The minimum cable cross-section is 10 mm² (7 AWG).
From: Danfoss VLT® AutomationDrive FC 301/302 0.25–75 kW Operating Guide