Danfoss VLT AutomationDrive FC 302 Operating Guide

Danfoss VLT AutomationDrive FC 302 Operating Guide

User Manual 160 pages · 13 MB · EN

This operating guide provides instructions for the safe installation and commissioning of the VLT AutomationDrive FC 302 variable frequency drive, covering enclosure sizes D1h through D8h. It is intended for use by qualified personnel and includes detailed safety precautions regarding high voltage, unintended motor starts, and discharge times. The manual outlines the intended use, product overview, and mechanical and electrical installation requirements.

Read online

Danfoss VLT® AutomationDrive FC 302 specifications

Rated power range315–710 kW
Enclosure sizesE1h, E2h, E3h, E4h
Protection rating, E1h/E2hIP21/Type 1 or IP54/Type 12
Protection rating, E3h/E4hIP20/chassis
Height, E1h/E2h2043 mm (80.4 in)
Height, E3h/E4h1578 mm (62.1 in)
Weight, E1h295 kg (650 lb)
Weight, E2h318 kg (700 lb)
Leakage currentGreater than 3.5 mA
Output frequency limit, software 6.72 and later590 Hz

Source: Danfoss VLT AutomationDrive FC 302 Frequency Converter Operating Guide

All Danfoss VLT® AutomationDrive FC 302 documents by type

Questions answered in these manuals

What enclosure sizes are covered by this operating guide?

It covers E1h, E2h, E3h, and E4h enclosure sizes.

From: Danfoss VLT AutomationDrive FC 302 Frequency Converter Operating Guide

How long should I wait before maintenance after disconnecting power?

Wait 40 minutes for the DC-link capacitors to discharge before maintenance or repair.

From: Danfoss VLT AutomationDrive FC 302 Frequency Converter Operating Guide

Who is qualified to install or operate this drive?

Only qualified personnel are allowed to install or operate this equipment.

From: Danfoss VLT AutomationDrive FC 302 Operating Guide

What is the minimum waiting time before performing service work?

The minimum waiting time is 20 minutes to allow capacitors to discharge fully.

From: Danfoss VLT AutomationDrive FC 302 Operating Guide

What is the maximum output frequency of the drive?

From software version 6.72 onwards, the output frequency is limited to 590 Hz due to export control regulations.

From: VLT® AutomationDrive FC 302 315–710 kW, Enclosure Sizes E1h–E4h Operating Guide

What are the enclosure sizes supported by this drive?

The drive supports enclosure sizes E1h, E2h, E3h, and E4h.

From: VLT® AutomationDrive FC 302 315–710 kW, Enclosure Sizes E1h–E4h Operating Guide