Key facts
- Brand
- Tektronix
- Model
- 80C00 and 80E00 Series
- Category
- Other Electronics
- Industry
- Electronics
- Documents
- 3
- Languages
- EN
- Last added
- 2026-11-20
Start here

Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
This document is the user manual for the Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules. It covers general safety, EMC compliance, and environmental considerations, as well as specific instructions for handling modules to prevent electrostatic damage. The guide details how to install or remove modules, verify their installation, and use them to take measurements. It also explains module controls and indicators, and provides guidelines for connecting both optical and electrical signals.
Read onlineTektronix 80C00 and 80E00 Series specifications
| SMA connector torque | 56 N-cm (5 in-lb) ±5.6 N-cm (±0.5 in-lb) |
|---|---|
| 1.85 mm, 2.4 mm, 2.92 mm, and 3.5 mm connector torque | 90 N-cm (8 in-lb) ±9.0 N-cm (±0.8 in-lb) |
| Warranty period | One (1) year from date of shipment |
Source: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
All Tektronix 80C00 and 80E00 Series documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How long is the product warranty?
Tektronix warrants the product to be free from defects in materials and workmanship for one (1) year from the date of shipment.
From: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
Where can I find EMC compliance information?
Because the modules are used only when installed in the main instrument, EMC compliance information is in the primary instrument user documentation.
From: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
How should modules be handled to prevent damage?
Follow the guidelines in the 'How to handle modules to prevent electrostatic damage' section to avoid electrostatic damage.
From: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
What is the warranty period for the product?
Tektronix warrants the product will be free from defects in materials and workmanship for one year from the date of shipment.
From: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
What is the warranty period for these modules?
Tektronix warrants that the product will be free from defects in materials and workmanship for a period of one year from the date of shipment.
From: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual
What is the torque setting for SMA electrical connectors?
The recommended torque setting for SMA connectors is 56 N-cm (5 in-lb) with a tolerance of ±5.6 N-cm.
From: Tektronix 80C00 and 80E00 Series Optical and Electrical Sampling Modules User Manual