Tektronix 4/5/6 Series MSO User Manual Printable Help
This printable help guide provides detailed information for the Tektronix 4/5/6 Series MSO oscilloscopes (MSO44, MSO46, MSO54, MSO56, MSO58, MSO58LP, MSO64). It includes licensing information, installation steps, power‑on procedures, and how to configure the instrument for both bench and rack‑mount use.
The manual describes the user interface, front‑panel controls, and a wide range of measurement and analysis functions such as waveform acquisition, trigger setup, spectrum view, and advanced power and jitter analysis. It also lists optional accessories, probe compatibility, and network connectivity options.
Tektronix 6 Series MSO specifications
| Input channels | 4 FlexChannel inputs, each 1 analog or 8 digital inputs |
|---|---|
| Bandwidth | 1 GHz, 2.5 GHz, 4 GHz, 6 GHz, 8 GHz (upgradable) |
| Sample rate | 25 GS/s real-time, 2.5 TS/s interpolated |
| Record length | 62.5 M points standard; 125 M and 250 M points optional |
| Waveform capture rate | >500,000 waveforms/second |
| Vertical resolution | 12-bit ADC, up to 16 bits in high resolution mode |
| Display | 15.6-inch (396 mm) TFT color, 1920 x 1080 capacitive multi-touch |
| Arbitrary waveform/function generator | 50 MHz waveform generation (option) |
| Dimensions | 309 mm high x 454 mm wide x 204 mm deep |
| Weight | <28.4 lb (12.88 kg) |
| Warranty | 3-year standard warranty |
Source: Tektronix 6 Series MSO Mixed Signal Oscilloscope Product Datasheet
All Tektronix 6 Series MSO documents by type
How to use the product for one specific task, with worked examples.
Instruction set, parameters and examples for configuring or programming the device.
Mounting, wiring and first power-up. Read it before the hardware goes in.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
How many digital channels can the 6 Series MSO provide?
Each FlexChannel input accepts a TLP058 logic probe with 8 digital inputs, and multiple TLP058 probes can be connected for up to 32 digital channels.
From: Tektronix 6 Series MSO Mixed Signal Oscilloscope Product Datasheet
Can the bandwidth of the 6 Series MSO be upgraded?
Yes, the datasheet lists bandwidths of 1, 2.5, 4, 6 and 8 GHz and marks the bandwidth as upgradable.
From: Tektronix 6 Series MSO Mixed Signal Oscilloscope Product Datasheet
What is the maximum bandwidth of the 6 Series MSO?
The maximum bandwidth is 8 GHz.
From: Tektronix 6 Series MSO Mixed Signal Oscilloscope Product Data Sheet
How many digital logic inputs can be supported?
Up to 32 digital channels can be supported using TLP058 probes.
From: Tektronix 6 Series MSO Mixed Signal Oscilloscope Product Data Sheet
Which firmware versions include the PI Translator?
The oscilloscopes come equipped with this translator in firmware versions v1.30 and higher.
From: Tektronix 5 and 6 Series MSO PI Command Translator Technical Brief
What is the default file location for the Compatibility File on Windows?
The default location when running Windows is C:\Users\Public\Tektronix\TekScope\PICompatibility\.
From: Tektronix 5 and 6 Series MSO PI Command Translator Technical Brief