Haier KFR-60LW Manuals

ManualLib has 5 documents for the Haier KFR-60LW (Air conditioner): 5 installation guides. Every file can be read online or downloaded as a PDF for free.

Installation Guide 5

Key facts

Brand
Haier
Model
KFR-60LW
Industry
Appliances
Documents
5
Languages
ZH
Last added
2012-02-25

Start here

Haier KFR-50LW/02CDF23 KFR-60LW/02CDF23 KFR-72LW/02CDF23 Installation Manual

Haier KFR-50LW/02CDF23 KFR-60LW/02CDF23 KFR-72LW/02CDF23 Installation Manual

Installation Guide 2 pages · 1.9 MB · ZH

This manual provides step‑by‑step instructions for safely installing Haier KFR‑50LW/02CDF23, KFR‑60LW/02CDF23 and KFR‑72LW/02CDF23 split‑type air conditioners. It includes safety precautions, required electrical wiring, indoor and outdoor unit mounting, refrigerant charging, and initial system testing.

Additional sections cover routine maintenance such as filter cleaning, seasonal care, remote‑control operation, and troubleshooting tips like setting the power‑off compensation and static‑sleep functions. This manual is written in Chinese.

Read online

Haier KFR-60LW specifications

Power Supply1PH, 220V~, 50Hz
Cooling Capacity (KFR‑50LW)6000 W (1000‑6600 W)
Cooling Capacity (KFR‑60LW)7200 W (1000‑7600 W)
Cooling Capacity (KFR‑72LW)5000 W (1000‑6000 W)

Source: Haier KFR-50LW/02CDF23 KFR-60LW/02CDF23 KFR-72LW/02CDF23 Installation Manual

All Haier KFR-60LW documents by type

Questions answered in these manuals

How do I set the power‑off compensation function?

With the remote on, press the sleep key 10 times within 5 seconds; the buzzer will sound four times and the unit enters power‑off compensation mode.

From: Haier KFR-50LW/02CDF23 KFR-60LW/02CDF23 KFR-72LW/02CDF23 Installation Manual

How should the indoor filter be cleaned?

Remove the filter, wash it with water or a neutral detergent, avoid water hotter than 40 °C, rinse, dry and reinstall.

From: Haier KFR-50LW/02CDF23 KFR-60LW/02CDF23 KFR-72LW/02CDF23 Installation Manual

How do I set the power‑outage compensation function?

Press the remote’s sleep key 10 times within 5 seconds; the buzzer will sound four times and the unit enters power‑outage compensation mode.

From: Haier KFR-50LW/03CCQ23 KFR-60LW/03CCQ23 KFR-72LW/03CCQ23 Installation Guide

Which refrigerant should be used for charging?

Only R410A may be used; using any other refrigerant can cause abnormal pressure and safety hazards.

From: Haier KFR-50LW/03CCQ23 KFR-60LW/03CCQ23 KFR-72LW/03CCQ23 Installation Guide

What type of battery does the remote control use?

The remote uses two 7 V batteries; replace both with new matching batteries when the display fades.

From: Haier household air conditioner KFR -50LW/03HBF23 KFR-60LW/03HBF23 seriesmakeuse installation Manual

What is the required power supply for the indoor unit?

A dedicated single‑phase 220 V, 50 Hz supply with a fuse rated 20 A (30 A for larger models) is required.

From: Haier household air conditioner KFR -50LW/03HBF23 KFR-60LW/03HBF23 seriesmakeuse installation Manual