Haier KFR-50LW/02CDF23 / KFR-60LW/02CDF23 / KFR-72LW/02CDF23 Air Conditioner Installation Guide

The document mainly introduces the safety precautions and instructions for using Haier air conditioners, including using control panels or remote controls to operate the machines, not spraying paint or insecticides on the machine surface, and disconnecting the power when not in use. It also mentions some taboos for using air conditioners, such as not installing them in flammable, explosive, or corrosive gas environments. In addition, it introduces Haier's warranty policy and charging standards.


Haier KFR-50LW/02CDF23 / KFR-60LW/02CDF23 / KFR-72LW/02CDF23 Air Conditioner Installation Guide - cover page
Brand
Haier
Category
Air conditioner
Document type
Installation Guide
Language
Chinese
Pages
2
File format
PDF
File size
5.4 MB
Updated
28 September, 2023
MD5 checksum
13FF1D4ACA7B3AC8C7EECC9D4F00375F

About this manual

This Haier installation guide covers the KFR-50LW/02CDF23, KFR-60LW/02CDF23, and KFR-72LW/02CDF23 split floor-standing room air conditioners. It includes safety precautions, pre-installation preparation, wiring and terminal connection methods, piping layout, refrigerant charging, vacuum pumping, indoor unit installation, and a trial-operation checklist.

The guide also lists technical data for the applicable models, including cooling and heating capacity, input power and current, noise, weight, indoor unit air circulation, and dimensions. It also describes the power failure compensation function and the Haier warranty and service terms for household air conditioners. This manual is written in Chinese.

What's inside

  • 安全注意事项
  • 安装前准备
  • 接线方法
  • 管路布置
  • 安装说明
  • 室内机安装
  • 用真空泵抽真空的步骤
  • 安装检查及试运转
  • 使用保养介绍
  • 停电补偿功能

Specifications

Power supply1PH, 220V~, 50Hz
KFR-50LW/02CDF23 cooling capacity5000 W (1000-6400 W)
KFR-50LW/02CDF23 heating capacity6100 W (1000-7700 W)
KFR-50LW/02CDF23 cooling input power1570 W
KFR-50LW/02CDF23 heating input power1900 W
KFR-50LW/02CDF23 noise52/34/39 dB(A) (indoor/outdoor/indoor unit)
KFR-50LW/02CDF23 indoor unit dimensions500 x 1760 x 260 mm
KFR-50LW/02CDF23 outdoor unit dimensions780 x 650 x 250 mm
KFR-50LW/02CDF23 indoor unit air circulation2500 m3/h
KFR-60LW/02RA1(R2DBPF)-S3 cooling capacity7200 W (1000-7700 W)
KFR-60LW/02RA1(R2DBPF)-S3 heating capacity8400 W (1000-10000 W)
KFR-60LW/02RA1(R2DBPF)-S3 cooling input power2820 W
KFR-60LW/02RA1(R2DBPF)-S3 heating input power3100 W
KFR-60LW/02RA1(R2DBPF)-S3 cooling current13.1 A
KFR-60LW/02RA1(R2DBPF)-S3 heating current14.1 A
KFR-60LW/02RA1(R2DBPF)-S3 noise56/34/47 dB(A)
KFR-60LW/02RA1(R2DBPF)-S3 indoor unit dimensions500 x 1760 x 260 mm
KFR-60LW/02RA1(R2DBPF)-S3 outdoor unit dimensions810 x 680 x 288 mm
KFR-72LW/02RA1(R2DBPF)-S3 cooling capacity7400 W (1000-9800 W)
KFR-72LW/02RA1(R2DBPF)-S3 heating capacity7100 W
KFR-72LW/02RA1(R2DBPF)-S3 cooling input power2100 W
KFR-72LW/02RA1(R2DBPF)-S3 heating input power2500 W
KFR-72LW/02RA1(R2DBPF)-S3 noise54/34/47 dB(A)
KFR-72LW/02RA1(R2DBPF)-S3 indoor unit dimensions500 x 1760 x 260 mm
KFR-72LW/02RA1(R2DBPF)-S3 outdoor unit dimensions810 x 680 x 288 mm
RefrigerantR410A
StandardGB/T 7725-2004
Dedicated switch rating20A or above for 60 model; 30A or above for 72 model
Vacuum level-0.1 Kpa (-76cm/g) or below
Refrigerant added charge by pipe length5 m: none; 10 m: 300 g; 15 m: 600 g; 20 m: 900 g
Connection cable specification4x0.75mm2 and above
Power cable specification2.5mm2 and above

Frequently asked questions

What power supply is required for the Haier KFR-50LW/02CDF23, KFR-60LW/02CDF23, and KFR-72LW/02CDF23 air conditioners?

The units use a single-phase 220V~, 50Hz power supply with power supplied from the outdoor unit. A dedicated switch and grounded power line are required, and the ground wire and neutral wire must be kept separate.

How is the power failure compensation function set and canceled?

With the remote control powered on and the sleep key active, press the sleep key 10 times within 5 seconds; four beeps confirm that power failure compensation is set, and two beeps confirm that it is canceled.

How should the piping be arranged during installation?

Place the drain pipe below, slope it so there are no upward bulges or downward dips, and insulate the drain hose with thermal material if the ambient humidity is high.

What steps are required to evacuate the refrigerant lines with a vacuum pump?

Remove the service valve caps, connect the hose to the three-way service valve, manifold gauge, and vacuum pump, open the low-pressure knob, and run the vacuum pump for about 15 minutes until the reading reaches -0.1 Kpa (-76cm/g) or below. Then close the low-side knob and pump, hold for 1-2 minutes, and check that the gauge does not drift back before opening the valves fully.