Fluke 39/41B Power Harmonics Tester Users Manual
The Fluke 39/41B Power Harmonics Tester is designed for measuring voltage and current harmonics on industrial power distribution circuits. The device features eight nonvolatile memories capable of storing 2048 sampled points of waveform data for both voltage and current inputs, allowing for later recall or transmission to a computer. It includes various screen modes such as Waveform, Harmonics, and Text to display measurement data effectively.
Read onlineFluke 41B specifications
| Overload Protection | 600V maximum |
|---|---|
| Surge Protection | 6 kV |
| Maximum Voltage Isolation | 600V from any terminal |
| Memory Storage | 2048 sampled points |
| Interface Baud Rate | 9.6, or 19.2k baud |
All Fluke 41B documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What is the maximum voltage for the tester's input?
The maximum voltage for the Voltage or Current Probe Input is 600V.
How many sampled points of waveform data can be stored?
The device stores 2048 sampled points of waveform data for both Voltage and Current inputs.
What is the warranty period for Fluke products?
The warranty period is one year from the date of shipment.
How long are parts, repairs, and services covered under warranty?
Parts, product repairs, and services are warranted for 90 days.