Fluke Ti40/Ti45/Ti50/Ti55 Infrared Thermal Imager User Manual
This manual introduces the Fluke Ti40/Ti45/Ti50/Ti55 infrared thermal imagers, outlines safety precautions, warranty details, and the standard accessories included with the devices. It also explains how to charge and insert the battery, power the imager, and insert storage cards.
The guide covers basic operation such as focusing, setting temperature spans, capturing images, using SmartView software, and advanced features like electronic zoom, image analysis, emissivity settings, and palette adjustments. A full specification table for each model is provided in the appendix. This manual is written in Chinese.
Fluke TI40 specifications
| Detector resolution | 160 × 120 |
|---|---|
| Temperature sensitivity (NETD) | 0.08 °C |
| Temperature range | -20 °C to +600 °C |
| High‑temperature option | up to 1200 °C |
| Lens options | 10.5 mm, 20 mm, 54 mm |
Source: Fluke TI40/TI45 Infrared Thermal Imaging Instrument Manual
All Fluke TI40 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Fluke TiR2/TiR3/TiR4/Ti40/Ti45/Ti50/Ti55 User Manual 134 p
- Fluke TI40/TI45 Infrared Thermal Imaging Instrument Manual 1 p
- FLUKE TiR2/3/4 Ti40/45/50/55 user manual
- Fluke TiR2/TiR3/TiR4/Ti40/Ti45/Ti50/Ti55 IR FlexCam Thermal Imager User Guide 20 p
- Fluke Ti40/Ti45/Ti50/Ti55 Infrared Thermal Imager User Manual 136 p
Questions answered in these manuals
How can I adjust the temperature span?
The manual provides both manual and automatic temperature span adjustments under the “手动水平和跨度调整” and “自动水平和跨度调整” sections.
How do I add annotations to images in SmartView?
Create an annotation list in SmartView as explained in the “在 SmartView 中创建附注列表” section.
What is the detector resolution of the TI40/TI45 series?
It uses a 160 × 120 detector.
From: Fluke TI40/TI45 Infrared Thermal Imaging Instrument Manual
What temperature sensitivity does the instrument provide?
The temperature sensitivity is 0.08 °C NETD.
From: Fluke TI40/TI45 Infrared Thermal Imaging Instrument Manual
How long must the thermal imager pre‑heat before accurate measurements?
The imager must pre‑heat for three minutes before accurate measurements can be taken.
From: Fluke TiR2/TiR3/TiR4/Ti40/Ti45/Ti50/Ti55 IR FlexCam Thermal Imager User Guide
What safety warning is given about the laser indicator?
The device contains a 2‑level laser indicator and you should not point the laser directly at eyes or reflective surfaces.
From: Fluke TiR2/TiR3/TiR4/Ti40/Ti45/Ti50/Ti55 IR FlexCam Thermal Imager User Guide