Key facts
- Brand
- Fluke
- Model
- 62 MAX
- Industry
- Industrial
- Documents
- 7
- Languages
- ZH · EN · ES · FR
- Last added
- 2026-10-26
Start here

Fluke 62 MAX/62 MAX+ Infrared Thermometer Users Manual
This is the Spanish-language users manual (Manual de uso) for the Fluke 62 MAX and 62 MAX+ infrared thermometers, published by Fluke Corporation in April 2012 (PN 4060712, Rev. 1). It explains that the Product determines surface temperature by measuring the amount of infrared energy radiated by the surface of an object, and notes that Japanese models show only degrees Celsius.
The manual gives Fluke contact and registration information, detailed warning and caution statements for safe use (including laser warnings), a table of the symbols used on the product and in the manual, and maintenance instructions for changing the AA battery and cleaning the housing. It also contains a table of contents pointing to sections on specifications, agency standards and approvals, and illustrations of the product. This manual is written in Spanish.
Fluke 62 MAX specifications
| Temperature Range (62 MAX) | -30 °C to 500 °C (-22°F to 932 °F) |
|---|---|
| Temperature Range (62 MAX +) | -30 °C to 650 °C (-22°F to 1202 °F) |
| Accuracy (≥0 °C) 62 MAX | ±1.5 °C or ±1.5% of reading, whichever is greater |
| Accuracy (≥0 °C) 62 MAX + | ±1 °C or ±1% of reading, whichever is greater |
| Response Time (95%) 62 MAX | <500 ms |
| Response Time (95%) 62 MAX + | <300 ms |
| Spectral Response | 8 to 14 microns |
| Emissivity Range | 0.10 to 1.00 |
Source: Fluke 62 MAX/62 MAX + Industrial Radiation Thermometer User Manual
All Fluke 62 MAX documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Fluke 62 MAX/62 MAX + Industrial Radiation Thermometer User Manual 21 p
- Fluke 62 MAX/62 MAX+ Infrared Thermometer Users Manual 22 p
- Fluke 62 MAX/62 MAX + Infrared Thermometer Users Manual 22 p
- Fluke 62 MAX/62 MAX + Infrared Thermometer Users Manual 20 p
- Fluke 62 MAX/62 MAX+ Infrared Thermometer Calibration Information 10 p
Questions answered in these manuals
What type of batteries are required for the Fluke 62 MAX/62 MAX +?
The device requires AA IEC LR06 batteries.
From: Fluke 62 MAX/62 MAX + Industrial Radiation Thermometer User Manual
How should the product be cleaned?
Clean the exterior with a sponge or soft cloth dampened with soapy water, and carefully wipe surfaces with a moist cotton swab.
From: Fluke 62 MAX/62 MAX + Industrial Radiation Thermometer User Manual
What is the temperature range of the Fluke 62 Max?
The Fluke 62 Max measures from -30 °C to 500 °C (-22 °F to 932 °F).
From: Fluke 62 Max and 62 Max+ IR Thermometers Product Leaflet
What is the temperature range of the Fluke 62 Max+?
The Fluke 62 Max+ measures from -30 °C to 650 °C (-22 °F to 1202 °F).
From: Fluke 62 Max and 62 Max+ IR Thermometers Product Leaflet
¿Cómo cambio la batería del termómetro?
Abra el compartimento de las baterías e instale o sustituya la batería AA IEC LR06, tal como se muestra en la figura correspondiente.
From: Fluke 62 MAX/62 MAX+ Infrared Thermometer Users Manual
¿Cómo se limpia el producto?
Use jabón y agua con una esponja humedecida o un paño suave para limpiar la carcasa, y limpie con cuidado la superficie con un bastoncillo de algodón húmedo.
From: Fluke 62 MAX/62 MAX+ Infrared Thermometer Users Manual
