Key facts
- Brand
- Fluke
- Model
- 725EX
- Industry
- Industrial
- Documents
- 7
- Languages
- EN · ZH
- Last added
- 2023-10-18
Start here

Fluke 725Ex Multifunction Process Calibrator Users Manual
The Fluke 725Ex Multifunction Process Calibrator is a handheld device designed for measuring and sourcing electrical parameters, temperature, and pressure. It features a dual-display interface and supports hazardous area applications with Ex certification. The device allows users to calibrate transmitters, simulate signals, and perform switch tests.
Read onlineFluke 725EX specifications
| DC Voltage Measure | 0 V dc to 30 V dc |
|---|---|
| DC Voltage Source | 0 V dc to 10 V dc |
| DC mA Measure | 0 to 24 mA dc |
| Frequency Measure | 1 CPM to 10 kHz |
| Thermocouple Types | E, J, K, T, B, R, S, L, U, N, mV, XK, BP |
| RTD Types | Ni120, Pt100, Pt200, Pt500, Pt1000 |
| Pressure Measurement Modules | Fluke 750PEx series modules ranging from 10 inH2O to 3000 psi |
| Intrinsic Safety Max Voltage | 30 V |
Source: Fluke 725Ex Multifunction Process Calibrator Users Manual
All Fluke 725EX documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- Fluke 725Ex Multifunction Process Calibrator Users Manual 65 p
- Fluke 725Ex Multifunction Process Calibrator Users Manual 70 p
- Fluke 725Ex User Manual 70 p
- Fluke 725Ex Multifunction Process Calibrator User Manual 70 p
- Fluke 725Ex Process Calibrator User Manual 70 p
- Fluke 725Ex Multifunction Process Calibrator User Manual 70 p
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
What is the warranty period for the Fluke 725Ex?
The warranty period is three years and begins on the date of shipment.
From: Fluke 725Ex Multifunction Process Calibrator Users Manual
Can the Fluke 725Ex be used in hazardous areas?
Yes, the Model 725Ex calibrator is designed for use in Ex Hazardous Areas as an intrinsically safe instrument.
From: Fluke 725Ex Multifunction Process Calibrator Users Manual
What is the warranty period for the Fluke 725Ex?
The warranty period is three years and begins on the date of shipment.
From: Fluke 725Ex Multifunction Process Calibrator Users Manual
What batteries are approved for the Fluke 725Ex?
The device requires 4 AA alkaline batteries.
From: Fluke 725Ex Multifunction Process Calibrator Users Manual
What is the maximum voltage that can be applied between the input terminals?
You must never apply more than 30.0 V between the input terminals or between any terminal and earth ground.
From: Fluke 725Ex Multifunction Process Calibrator Calibration Manual
What happens if more than 30.0 V is applied to the input terminals?
Applying more than 30.0 V invalidates the Calibrator's Ex Approval and may cause permanent damage to the unit.
From: Fluke 725Ex Multifunction Process Calibrator Calibration Manual