Agilent manuals, page 160
Agilent 1100 Series Real-time LC Run Mapping Application Note
Application Note 8 pages · 699 KB · ENThis application note describes a method for coupling nano-LC to MALDI mass spectrometry using the Agilent 1100 Series micro fraction collector with…
Effect of Nonvolatile Buffers on the Agilent 1100 Series LC/MSD Application Note
Application Note 6 pages · 448 KB · ENThis application note studies the effects of using nonvolatile phosphate buffers versus volatile ammonium acetate buffers in the Agilent 1100 Series LC/MSD…
Agilent Technologies Impact of Ion-Pair Reagents on LC/MS Analysis
Other 7 pages · 144 KB · ENThis technical paper examines how different ion-pair reagents affect chromatographic retention and MS signal response in LC/MS analysis.
Agilent Determination of LSD iso-LSD 2-Oxo-3-Hydroxy-LSD in Urine Using the HP1100 LC/MSD
Application Note 4 pages · 173 KB · ENThis document describes a rapid, sensitive LC/MS method for analyzing LSD, iso-LSD, and 2-oxo-3-hydroxy-LSD in urine using the Agilent HP 1100 system.
Agilent Multisignal LC/MS Analysis for Compound Screening Application Note
Application Note 4 pages · 119 KB · ENThis application note demonstrates using positive/negative polarity switching on the Agilent 1100 LC/MSD system to improve compound screening and method…
Agilent 1100 Series Automated On-line Derivatization Electrospray LC/MS Analysis of Anatoxin-a
Application Note 4 pages · 227 KB · ENThis application note describes a method for detecting trace levels of the neurotoxin anatoxin-a in drinking water using automated on-line derivatization…
Agilent Improving Productivity in the Determination of Parameters for Early In Vitro ADME Part 4
Application Note 4 pages · 181 KB · ENThis Application Note details the experimental setup and results of a plasma protein binding assay using Agilent's 1200 Series RRLC and 6410 LC/MS systems.
Agilent Improving the productivity of pharmacokinetic parameter determination Application Note
Application Note 8 pages · 478 KB · ENThis application note demonstrates how Agilent LC/MS/MS solutions increase productivity in bio-availability studies using rapid resolution columns and…
Agilent Improving Productivity in Early In Vitro ADME Part 3 Caco-2 Permeability Assay Application Note
Application Note 4 pages · 186 KB · ENThis application note details the experimental setup and results of a Caco-2 permeability assay using Agilent's RRLC, LC/MS, and MassHunter software for…
Agilent 6410 Triple Quadrupole Mass Spectrometer CYP450 Inhibition Application Note
Application Note 8 pages · 376 KB · ENThis application note describes using the Agilent 6410 triple quadrupole mass spectrometer with a BioTrove RapidFire system for high-throughput…
Agilent 6510 Q-TOF LC/MS Application Note
Application Note 12 pages · 469 KB · ENThis application note evaluates the impact of MS/MS fragment ion mass accuracy on peptide identification in shotgun proteomics using the Agilent 6510 Q-TOF.
Agilent Human 14 Multiple Affinity Removal System Application Note
Product Leaflet 6 pages · 654 KB · ENThis document describes the Agilent Human 14 column for depleting 14 high-abundant proteins from human serum and plasma to improve proteomic analysis.
Agilent 1100 Series HPLC Solution for High Abundance Protein Depletion Application Note
Application Note 8 pages · 422 KB · ENThis application note describes a complete Agilent 1100 HPLC solution and methods for removing six high-abundance proteins from human serum using the…
Agilent High Capacity Multiple Affinity Removal Column Application Note
Product Leaflet 6 pages · 577 KB · ENApplication note describing the Agilent High Capacity Multiple Affinity Removal Column for depleting top six proteins from human serum.
Agilent 3100 OFFGEL Fractionator Application Note: Immuno-depletion and Protein Peptide OFFGEL Electrophoresis for Plasm
Application Note 4 pages · 263 KB · ENThis application note describes combining immuno-depletion with protein or peptide OFFGEL electrophoresis using the Agilent 3100 OFFGEL Fractionator to…
