Agilent manuals, page 162
Agilent Probing 3D Structures of Surfactants
Application Note 4 pages · 507 KB · ENThis application note describes using Agilent MAC Mode AFM to image soft surfactant aggregates with minimal distortion compared to standard contact mode.
Agilent MAC Mode AFM Studies of DNA Kinking Application Note
Application Note 2 pages · 110 KB · ENThis application note describes using Agilent's MAC Mode AFM to study zinc-induced kinking in 168-bp DNA minicircles.
Agilent AFM Instrumentation Application Note
Application Note 4 pages · 604 KB · ENThis application note describes the use of Agilent AFM instrumentation for scanning probe studies of metalloproteins, specifically azurin and cytochrome…
Evolution of SPM for Biological Imaging Application Note
Application Note 12 pages · 487 KB · ENThis application note discusses the evolution of Scanning Probe Microscopes (SPM), focusing on Atomic Force Microscopy (AFM) and its applications in…
Agilent MAC Mode AFM Applications in Biology and Pharmaceuticals
Application Note 3 pages · 2.2 MB · ENThis application note demonstrates the use of Agilent MAC Mode AFM for visualizing biological samples like liposomes, DNA, and proteins in various environments.
Agilent In Situ Investigation of Corrosion via SPM Application Note
Application Note 4 pages · 873 KB · ENThis application note describes the use of Agilent Scanning Probe Microscopy (SPM) systems for in situ investigation of corrosion processes on metals like…
Agilent MAC Mode AFM Application Note: Manipulation of Gold Nanoparticles
Application Note 3 pages · 310 KB · ENThis application note describes the manipulation of gold nanoparticles in aqueous solutions using an Agilent AFM in MAC Mode.
Agilent Type IV AFM Probe Antibody Attachment Application Note
Application Note 4 pages · 137 KB · ENThis application note describes the protocol for attaching antibodies to Agilent Type IV AFM probes using sulfhydryl reactive PEG linkers.
Agilent 5500 AFM Oxygen-Free High-Resolution Electrochemical SPM Application Note
Application Note 4 pages · 1.1 MB · ENThis application note characterizes the oxygen-elimination capability of the Agilent 5500 AFM environmental chamber and demonstrates high-resolution in situ…
Agilent AFM Studies of Polyvinyl Alcohol Application Note
Application Note 3 pages · 472 KB · ENThis application note describes using an Agilent atomic force microscope to study polyvinyl alcohol properties under controlled temperature and humidity.
Agilent In-process control for Aripiprazole manufacturing with the Agilent 1120 Compact LC Agilent TC C18(2) columns Manual
Application Note 4 pages · 235 KB · ENThis application note demonstrates the use of the Agilent 1120 Compact LC and TC C18(2) columns for in-process control of Aripiprazole manufacturing.
Agilent Detector linearity testing for Aripiprazole quality control with the Agilent 1120 Compact LC Agilent TC C18(2) columns Manual
Application Note 4 pages · 176 KB · ENThis application note evaluates the detector linearity and precision of the Agilent 1120 Compact LC using Aripiprazole as a test compound.
Agilent System suitability testing for Aripiprazole quality control with the Agilent 1120 Compact LC Agilent TC C18(2) columns Manual
Application Note 4 pages · 180 KB · ENThis application note demonstrates system suitability testing for Aripiprazole quality control using the Agilent 1120 Compact LC and TC C18(2) columns.
Agilent System suitability testing for Tramadol quality control with the Agilent 1120 Compact LC Agilent TC C18(2) columns Manual
Agilent LC/MSD TOF Mass Accuracy Evaluation Application Note
Application Note 8 pages · 239 KB · ENThis application note evaluates the mass accuracy performance of the Agilent LC/MSD TOF using degradation products of amoxicillin as a sample.