Analog Devices AD7865 Manuals

ManualLib has 5 documents for the Analog Devices AD7865: 3 datasheets, 2 user manuals. Every file can be read online or downloaded as a PDF for free.

Datasheet 3User Manual 2

Key facts

Model
AD7865
Industry
Industrial
Documents
5
Languages
EN
Last added
2012-08-03

Start here

Interfacing AD7865 Parallel ADCs to ADSP-2136x SHARC Processors Application Note

Interfacing AD7865 Parallel ADCs to ADSP-2136x SHARC Processors Application Note

Application Note 7 pages · 500 KB · EN

This document details the interfacing of the AD7865, a 14-bit simultaneous sampling A/D converter, with third-generation SHARC processors like the ADSP-21365. It covers two specific connection schemes: the standard parallel port interface and the Parallel Data Acquisition Port (PDAP) interface.

Read online

Analog Devices AD7865 specifications

Resolution14-bit A/D converter
ChannelsFour channels
Sampling Speed2.4 us
Supply VoltageSingle 5 V supply
Power Consumption115 mW (typical)

Source: Interfacing AD7865 Parallel ADCs to ADSP-2136x SHARC Processors Application Note

All Analog Devices AD7865 documents by type

Datasheet 3

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What interfaces are described for connecting the AD7865 to SHARC processors?

The document describes two schemes: the parallel port interface and the parallel data acquisition port (PDAP) interface.

From: Interfacing AD7865 Parallel ADCs to ADSP-2136x SHARC Processors Application Note

How many channels does the AD7865 support?

The device supports four simultaneous sampling channels.

From: Interfacing AD7865 Parallel ADCs to ADSP-2136x SHARC Processors Application Note

What are the main applications for the AD7865?

Applications include AC motor control, uninterruptible power supplies, industrial power meters/monitors, and data acquisition systems.

From: Interfacing AD7865 Parallel ADCs to ADSP-21161 SHARC Processors Application Note

How does the ADSP-21161 generate the /CONVST signal?

The frame sync of SPORT0 is used to generate the /CONVST signal for the ADC.

From: Interfacing AD7865 Parallel ADCs to ADSP-21161 SHARC Processors Application Note

How many channels can be sampled simultaneously?

All four analog input channels are sampled simultaneously.

From: Analog Devices AD7865 Datasheet Rev B

What is the typical power consumption in normal mode?

Typical power dissipation is 115 mW in normal mode.

From: Analog Devices AD7865 Datasheet Rev B