Agilent manuals, page 48
Agilent's New Polymer Solid-Phase Extraction Cartridges: SampliQ OPT Technical Note Manual
Agilent SampliQ OPT uses Optimized Polymer Technology (OPT), a novel polyamide chemistry (patent pending). The result is a resin that exhibits retention for both polar and nonpolar compounds based on the balanced hydrophilic and hydrophobic properties of the polymer.
Agilent Achieving Unmatched Speed Confidence for Complex Sample Analyses: Agilent True High-Definition TOF Technology Manual
TOF and Q-TOF liquid chromatography/mass spectrometry technologies are improving rapidly and showing impressive gains in performance. Agilent's TOF and Q-TOF instruments deliver excellent performance in all dimensions simultaneously, including mass accuracy, resolution, dynamic range, sensitivity, and spectral acquisition speed. Agilent True High-Definition TOF technology achieves exceptional mass accuracy, high resolution, great sensitivity, wide dynamic range, and fast data acquisition rates without compromises.
Agilent More Chromatographic Power for the Agilent 1200 Series LC Manual
Introduces the performance improvements of the Agilent 1200 Series LC, including detection limits, analysis speed and solvent consumption, and provides experimental equipment configuration.
Agilent Reducing HPLC Solvent Consumption - Combating the worldwide shortage of acetonitrile by deploying short LC columns with small internal diameters particles Manual
This document introduces how to reduce HPLC solvent consumption by using short LC columns with small internal diameters and particles to combat the worldwide shortage of acetonitrile.
Agilent G3 Microarray Format Technical Drawings with Tolerances Manual
This document provides detailed specifications for Agilent G3 microarray formats and tolerances
Agilent Jet Stream Thermal Gradient Focusing Technology Manual
Agilent Jet Stream technology enhances sensitivity in ESI-MS by improving the desolvation and spatial focusing of ions. Super-heated nitrogen sheath gas effectively dries ions and concentrates them in a thermal confinement zone. Desolvation reduces noise. Full confinement of the spray by the super-heated nitrogen gas eliminates sample recirculation and reduces peak tailing.
Agilent Velocity11 Bravo Liquid Handling Platform: 96 Channel 10 L Tip Accuracy Precision Manual
This document describes the features and performance of the Velocity11 Bravo liquid handling platform, as well as the advantages of using this platform for automated liquid handling.
Agilent Bravo Automated Liquid Handling Platform: 96-Channel 10 L Tip Accuracy Precision Manual
This document introduces the Agilent Bravo Automated Liquid Handling Platform 96-Channel 10 µL Tip Accuracy and Precision Technical Overview.
Agilent Bravo Automated Liquid Handling Platform: 96-Channel 30 L Tip Accuracy Precision Manual
This document describes a method to measure the accuracy and precision of the Bravo in conjunction with a 96-Channel ST Disposable Tip Head. Measurements are determined by dispensing a tartrazine/DMSO solution into dry microplates, filling the plates with water, and measuring tartrazine absorbance. The product’s performance meets or exceeds CVs of 5% and accuracy of ±10% of the desired volume across the practical volume range.
Agilent Bravo Automated Liquid Handling Platform: 384-Channel 10 L Tip Accuracy Precision Manual
The Agilent Bravo Automated Liquid Handling Platform is a liquid handling device with 384-channel 10 µL tip accuracy and precision. It offers high accuracy, high precision, and high throughput.
Agilent Bravo Automated Liquid Handling Platform: 384-Channel 30 L Tip Accuracy Precision Manual
This document introduces the accuracy and precision technical overview of the Agilent Bravo Automated Liquid Handling Platform's 384-channel 30 µL tip
Agilent 384-Channel 30 L Tip Accuracy Precision with Multiple Tip Attachments Manual
This document describes the accuracy and precision of 30μL 384-channel tips, which are stable and constant over 100 cycles of tip attachment and detachment. Accuracy and precision are nearly as good on the 100th liquid transfer as they are on the first.
Agilent Bravo Automated Liquid Handling Platform: 384-Channel 70 L Tip Accuracy Precision Manual
This document introduces the accuracy and precision of the Agilent Bravo Automated Liquid Handling Platform 384-channel 70µL tip.
Agilent LC Columns for Reducing Solvent Use Waste Technical Overview Manual
This document introduces a method for reducing HPLC solvent use and waste. By changing the HPLC column while keeping the same bonded phase, it is possible to realize a 40 to 90 percent reduction in acetonitrile usage. Possibilities include reducing the diameter of the column, changing to a shorter column with a smaller particle size, or a simultaneous reduction of length, diameter, and particle size. These options are easy to implement, do not require redevelopment of the method, and in some cases significantly reduce the analysis time.
Agilent Multimode Inlet for Gas Chromatography Manual
Agilent Multimode Inlet is a gas chromatography inlet that can introduce a large amount of sample (5 µL to 250 µL or more) into Agilent 7890 Series GC systems, thereby reducing detection limits while maintaining high sample throughput and quality of results.