Agilent manuals, page 47
Agilent Ultron ES-OVM Column: A Bonded Ovomucoid Protein Column for Direct HPLC Separation of Chiral Compounds Manual
Agilent Performance Characterization of the High Sensitivity Protein 250 Assay for the Agilent 2100 Bioanalyzer Manual
This document introduces a new method for protein detection on the Agilent 2100 bioanalyzer based on fluorescent labeling. The method has high sensitivity, a large linear dynamic range, can detect impurities, and is fast and reliable.
Agilent Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software Manual
The Waters Empower 2 chromatography data software with ICS 1.05 fully supports Agilent 1200 Series Rapid Resolution LC (RRLC) systems with the exception of some special functionality. An Empower client-server system provides for easy installation and configuration of the Agilent 1200 Series RRLC system, support of all important parameters of the Agilent 1200 Series SL modules, evaluation of 2D, 3D and spectral raw data acquired by Agilent 1200 Series UV detectors, support of maintenance and diagnostics through Agilent Lab Monitor & Diagnostic software, and fast access to the Agilent 1200 Series RRLC system through the instant pilot controller.
Agilent Parts Selected by Agilent for LRM/MVS Services: Quality Criteria Performance Testing Manual
Agilent MVS provides the same high quality maintenance, repair and compliance services for non-Agilent chromatography instruments as we provide for comparable Agilent instruments.
Agilent's New Octadecylsilane (ODS) (C18) Solid-Phase Extraction Cartridges: SampliQ C18 Manual
sampliq c18 is the new generation of solid phase extraction products from agilent, with excellent reproducibility, high recoveries and multiple uses, can be used to extract neutral, weakly acidic and basic compounds, simple operation.
Agilent's New Mixed-Mode Anion Exchange Polymer Solid-Phase Extraction Cartridges: SampliQ SAX Manual
Agilent SampliQ SAX is a solid phase extraction (SPE) product that is suitable for acidic and neutral compounds. It offers excellent reproducibility, a simple extraction protocol and controlled particle size.
Agilent's New Mixed-Mode Cation Exchange Polymer Solid-Phase Extraction Cartridges: SampliQ SCX Manual
Agilent SampliQ SCX is a solid phase extraction (SPE) product that offers excellent reproducibility and high recoveries even when dried. It is suitable for basic and neutral compounds, with a simple extraction protocol and controlled particle size.
Agilent Probe Selection with Respect to the 5% Phenyl Ultra Inert Columns Offered by Agilent Technologies: Why Are There Two Test Mixtures Technical Overview Manual
Describes two test mixtures for Agilent J&W 5% phenyl ultra inert GC columns
Agilent Considerations in Microarray Scanning - ABRF Poster 2003 Manual
A method for quantifying the performance of a DNA microarray reader is described. The method uses standard microarray metrics such as detection limit, signal to noise, and the standard deviation of the log(ratio) to quantify the scanner's combined error. A method is also proposed to measure the scanner's contribution to the experimental error independently. This method can exclude error for other sources such as array synthesis, hybridization, wash and biology.
Agilent Microarray Format Technical Drawings with Tolerances Manual
This document contains technical drawings of Agilent Technologies' microarray formats, including 244K density microarray slides and the various formats available on these slides. The different formats of microarray slides have different features and characteristics.
Agilent An Improved Method for Automated Extension of Microarray Scanner Dynamic Range Manual
Agilent Secure Remote Monitoring Diagnostics for Agilent Systems Manual
Remote Advisor is a remote monitoring software provided by Agilent Technologies. It can proactively monitor critical laboratory system parameters, issue alerts when problems occur, remotely diagnose and resolve instrument problems, and provide reports on instrument and PC configurations, as well as instrument use and availability metrics.
Agilent J W High-Efficiency Capillary Columns: Productivity-Enhancing Tools for Fast GC Applications Manual
High-efficiency capillary columns (referred to as high-efficiency columns for short) are capillary columns with an inner diameter of less than 0.25 mm. Compared with conventional capillary columns with inner diameters of 0.25-0.32 mm, high-efficiency columns have higher theoretical plates (N) and higher peak capacities (µmol/m), which can achieve higher separation efficiency and lower analysis time. Agilent J&W high-efficiency columns use high-efficiency filling technology to ensure separation efficiency while maintaining good retention and reproducibility. Agilent J&W high-efficiency columns are suitable for applications in all fields of gas chromatography, including gas chromatography-mass spectrometry (GC-MS) and gas chromatography-mass spectrometry-time-of-flight (GC-MS-FTMS).
Agilent Performance Characteristics of the Agilent 1200 Series Variable Wavelength Detectors Faster results improved sensitivity absolute data security Manual
Agilent 1200 Series Variable Wavelength Detectors Performance Characteristics: Faster results, improved sensitivity and absolute data security
Agilent 3G Microarray Format Technical Drawings with Tolerances Manual
Technical drawings of Agilent 3G microarray formats, providing the sizes and features of the 1M, 2x400K, 4x180K and 8x60K formats
