Agilent The Triple-Axis Detector: Attributes Operating Advice Manual
The new Triple-Axis detector (TAD) uses a unique geometry and employs an improved electron multiplier design that will provide the user with several practical advantages. At a given operating gain, the new detector provides higher signal intensity by collecting more ions emerging from the quadrupole. Although signal is enhanced, neutral noise is substantially reduced through the off-axis design. Detector lifetime is also increased under proper operation.
Agilent Ion optics innovations for increased sensitivity in hybrid MS systems Manual
This document introduces the ion optics design innovations that contribute to the outstanding sensitivity of the Agilent Technologies 6400 Series Triple Quadrupole and 6500 Series Quadrupole Time-of-Flight LC/MS systems.
Agilent New Sample Preparation Protein Fractionation Techniques Manual
Agilent's Multiple Affinity Removal System is a polyclonal antibody-based system that rapidly depletes multiple high-abundance proteins in serum, plasma or CSF. The system was launched in August 2003 and remains the leading technology in this market.
Agilent GC-ICP-MS Helps Solve Biogas Usage Problem with Low Detection Limits for Siloxanes Manual
GC-ICP-MS technology helps solve the problem of low detection limits for siloxanes in biogas usage. It has low detection limits and high sensitivity. The technology allows for accurate quantification of any volatile Si containing compound based on the response of a single standard compound.
Agilent 1200 Series Rapid Resolution LC system - Switching between standard low delay volume configurations using a software-controlled high-pressure valve for optimized separation performance man
The Agilent 1200 Series RRLC system is designed for conventional LC with long columns of large internal diameter as well as for ultra-fast or rapid resolution LC with narrow bore column of about 2.1 mm id. Using a 600 bar, 2-position/6-port valve provides for switching between optimized conditions for both types of analysis.
Agilent Performance characteristics of the Agilent 1120 Compact LC Manual
This document introduces the performance characteristics of the Agilent 1120 Compact LC, including high precision time and area, precise gradient formation and excellent signal-to-noise ratio
Agilent GCRMA Probe Summarization Manual
This document introduces GCRMA usage.
Agilent RMA Probe Summarization Manual
This document introduces RMA (Robust Multi-array Analysis) method, which is used to normalize and summarize probe-level intensity measurements from Affymetrix Gene Chips ®.
Agilent miRNA Data Import Guide
This guide will step you through the process of importing Agilent miRNA data and setting up the experiment for analysis in GeneSpring GX 9.0.
Agilent 1200 Series Rapid Resolution LC system controlled by Chromeleon Supported modules tasks Manual
The document describes that the Dionex Chromeleon® 6.80 control software with service pack 3 and driver update 2c is able to fully support an Agilent 1200 Series Rapid Resolution LC (RRLC) system, except for some special functions. After installing the Chromeleon software and respective drivers, the Agilent 1200 Series RRLC system can be easily installed and configured, supports all important module parameters, evaluates raw data, including three-dimensional (3D) and two-dimensional (2D) data and spectra from Agilent ultraviolet (UV) detectors, supports maintenance and diagnostics with the Agilent Lab Monitor & Diagnostic software, can be quickly accessed using the Agilent 1200 Series instant pilot handheld controller, and executes some basic diagnostic/maintenance tasks from within Chromeleon.
Agilent DRS A.04 - The Latest in True Deconvolution Manual
DRS A.04 G1716AA is the latest revision, introduced in 2008, with features such as automatic, high-precision, and multi-functionality. It can automatically detect chemicals that violate the Chemical Weapons Convention, identify compounds at low concentration levels in complex matrices, and use retention time as a qualifier.
Agilent Retention Time Locking with the MSD Productivity ChemStation Manual
This document introduces the retention time locking (RTL) technology, which allows for the consistency of retention times on different instruments, simplifying method development and transfer.
Agilent A Comparison of Agilent Quick Amp Low RNA Input Linear Amplification Kits Manual
This document compares the Agilent Quick Amp and Low RNA Input Linear Amplification Kits and shows that both kits are equivalent when used for gene expression profiling.
Agilent Adding Retention Times to the METLIN Personal Metabolite Database to Improve Compound Identification Manual
A key step in metabolomics research is the identification of metabolites. Searching accurate-mass LC/MS data against metabolite databases is a powerful technique for identifying metabolites. Due to the presence of isobaric masses such as compound isomers and diastereomers, database searching by mass alone is generally insufficient for positive identification. Public databases do not contain retention time information and thus there is no way to resolve the issue of isobaric masses. However, with Agilent Technologies’ METLIN Personal metabolite database, empirically derived, method-specific retention times (RTs) can be added to compounds in the database, creating an accurate-mass retention time (AMRT) database. Retention times then provide a second match criterion orthogonal to, and independent of, compound mass. Searching an AMRT database provides a narrower, more focused list of possible metabolite identities. This technical note discusses the addition of retention times to the METLIN Personal metabolite database and provides a faster batch approach for creating an AMRT database.
Agilent Ultra Inert GC Columns: a New Tool from Agilent J Manual
Describes the role of gas chromatography (GC) column quality control test probes (QC test probes), including ensuring that the columns have been properly deactivated, contain the correct amount of stationary phase, and have the same relative retention as the last column purchased.