Agilent manuals, page 147
Agilent Glycoprotein sizing on the Agilent 2100 bioanalyzer
Glycoprotein sizing on the Agilent 2100 bioanalyzer
Agilent Differential proteome analysis: Two-dimensional nano LC/MS of E.coli proteome grown on different carbon sources
Differential proteome analysis: Two-dimensional nano LC/MS of E. coli proteome grown on different carbon sources
Agilent Testing ZORBAX GF-250 Performance Using Gel-Filtration Test Mixtures.
The document introduces the use of Gel-Filtration standards and the performance testing of ZORBAX GF-250 columns. The ZORBAX GF-250 column can effectively separate the components of the Bio-Rad® gel-filtration standard between thyroglobulin (670 KDa) and Vitamin B12 (1.35 KDa). The document also discusses the application and results of using gel-filtration test mixtures to test ZORBAX GF-250 columns.
Agilent Mutation detection for the K-ras P16 genes
This Application Note describes how to use the Agilent 2100 bioanalyzer to detect mutations in the K-ras and P16 genes.
Agilent Using the Agilent LC/MSD TOF to Identify Unknown Compounds
This document describes the use of mass spectrometry to identify unknown compounds in the pharmaceutical industry. By using a time-of-flight mass spectrometer with accurate mass capabilities, it is possible to determine the structure and composition of unknown compounds more accurately. This is important for the identification of unknown compounds during synthesis and manufacturing processes in the pharmaceutical industry.
Agilent Comparison of ZORBAX Poroshell 300Extend-C18 Totally Porous Packing in Achieving Very Rapid High-pH Separation of Proteins
The document introduces the advantages of ZORBAX Poroshell packings in the HPLC separation of large molecules such as proteins. This surface porous particle can make the separation faster. At high pH, peptides and small proteins can also be separated by using Extend-C18-bonded Poroshell particles. The high pH may be desirable for improving selectivity, solubility, ease of downstream processing, or to change signal-to-noise and charge-state in LC/MS. By extending the gradient time, it is possible to achieve even higher resolution in typical run times of 10 to 20 min.
Agilent Scale-Up of Protein Separations from Analytical to Semipreparative HPLC
This document introduces the method of using ZORBAX 300SB analytical column for protein separation. By optimizing the method, a quick and easy scale-up from analytical to semi-preparative HPLC can be achieved.
Agilent Using the High-pH Stability of ZORBAX Poroshell 300Extend-C18 to Increase Signal-to-Noise in LC/MS
ZORBAX Poroshell 300Extend-C18 is a high-pH stable column for LC/MS applications that can improve signal-to-noise ratio
Agilent Rapid Resolution HT Columns Maintain High Resolution with Agilent In-Line (Pre-Column) Filters
Agilent Improved LC Analysis of Human Serum Albumin Tryptic Digest Using 1.8-mm ZORBAX Rapid Resolution HT SB-C18 Column
The document demonstrates the improved liquid chromatography analysis of complex biological fluids using fine particle columns by comparing two columns of different lengths and particle sizes on the analysis of a tryptic digest of human serum albumin (HSA). The columns provide better resolution and comparable sensitivity to 150-mm columns, but in one-sixth the time.
Agilent Flow cytometric analysis of a limited number of cells using the Agilent 2100 bioanalyzer
This document describes the method for using the Agilent 2100 bioanalyzer to perform flow cytometric analysis of a limited number of cells.
Agilent Eclipse XDB-CN Provides Excellent Selectivity Resolution for Urea Pesticides
This document introduces the application of the Agilent ZORBAX Eclipse XDB-CN column, which can be used to analyze complex mixtures containing both polar and nonpolar components, such as pesticide mixtures.
Agilent HPLC Separation of Norethindrone Mestranol Using Progesterone as an Internal Standard on Eclipse XDB-CN (L10 USP) Eclipse XDB-C8 (L7 USP) Columns
This study investigated the comparison of USP-L10 and USP-L7 columns for dissolution and assay testing of norethindrone/mestranol tablets. The results showed that the USP-L10 column provided better peak separation for dissolution testing, while the USP-L7 column provided higher recovery for assay testing.
Agilent Interpreting mRNA electropherograms
This document introduces the importance of Agilent 2100 bioanalyzer in mRNA sample quality assessment, and provides detailed usage methods and precautions.
Agilent Applications features of the Agilent 1100 Series micro fraction collector
The Agilent 1100 Series micro fraction collector is a high-performance solution for processing complex samples in applications such as proteomics, metabolomics, natural product research, and library generation. This Application Note describes the field of application for the Agilent 1100 Series micro fraction collector and discusses the features and software control of this device. In addition, the main modules of the micro fraction collection system are also discussed.
