Lincoln Electric PC208 & PC210 Welding Power Source User Manual

Lincoln Electric PC208 & PC210 Welding Power Source User Manual

User Manual 14 pages · 1.7 MB · RO

This document is the Romanian user manual for the INVERTEC PC208 and PC210 welding power sources manufactured by Lincoln Electric. It provides technical specifications, installation and usage instructions, electromagnetic compatibility (EMC) guidelines, and safety warnings for operators.

Read online

Lincoln Electric PC208 specifications

Input Power (60% duty)2.5 kW
Input Power (35% duty)3 kW
Output Current (100% duty)15 A
Dimensions (H x W x D)385 x 215 x 480 mm

Source: Lincoln Electric PC208 & PC210 Welding Power Source User Manual

All Lincoln Electric PC208 documents by type

Questions answered in these manuals

Is the equipment suitable for residential use?

No, the equipment is Class A and not intended for use in residential locations supplied by a public low-voltage power system.

From: Lincoln Electric PC208 & PC210 Welding Power Source User Manual

What is the duty cycle of the machine?

The duty cycle is the percentage of time in a 10 minute cycle at which the operator can operate the machine at rated cutting current.

From: Lincoln Electric PC208/210 Inverter Cold Plasma Cutting Machine Operator's Manual

What is the maximum ambient temperature for operating this machine?

The machine must not be operated in areas where the ambient temperature exceeds 40°C.

From: Lincoln Electric PC208/210 Inverter Cold Plasma Cutting Machine Operator's Manual

What is the maximum ambient temperature for operation?

The machine must not be operated in areas with an ambient temperature greater than 40°C.

From: Lincoln Electric INVERTEC PC208 and PC210 Operator's Manual

What are the maximum ambient temperature limits for operating this machine?

The machine must not be operated in areas where the ambient temperature exceeds 40°C.

From: Lincoln Electric INVERTEC PC208 and PC210 Operator's Manual