Key facts
- Brand
- Lincoln Electric
- Model
- PC208
- Category
- Industrial Robot
- Documents
- 3
- Languages
- RO · EN
- Last added
- 2023-10-15
Start here

Lincoln Electric PC208 & PC210 Welding Power Source User Manual
This document is the Romanian user manual for the INVERTEC PC208 and PC210 welding power sources manufactured by Lincoln Electric. It provides technical specifications, installation and usage instructions, electromagnetic compatibility (EMC) guidelines, and safety warnings for operators.
Read onlineLincoln Electric PC208 specifications
| Input Power (60% duty) | 2.5 kW |
|---|---|
| Input Power (35% duty) | 3 kW |
| Output Current (100% duty) | 15 A |
| Dimensions (H x W x D) | 385 x 215 x 480 mm |
Source: Lincoln Electric PC208 & PC210 Welding Power Source User Manual
All Lincoln Electric PC208 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Is the equipment suitable for residential use?
No, the equipment is Class A and not intended for use in residential locations supplied by a public low-voltage power system.
From: Lincoln Electric PC208 & PC210 Welding Power Source User Manual
What is the duty cycle of the machine?
The duty cycle is the percentage of time in a 10 minute cycle at which the operator can operate the machine at rated cutting current.
From: Lincoln Electric PC208/210 Inverter Cold Plasma Cutting Machine Operator's Manual
What is the maximum ambient temperature for operating this machine?
The machine must not be operated in areas where the ambient temperature exceeds 40°C.
From: Lincoln Electric PC208/210 Inverter Cold Plasma Cutting Machine Operator's Manual
What is the maximum ambient temperature for operation?
The machine must not be operated in areas with an ambient temperature greater than 40°C.
From: Lincoln Electric INVERTEC PC208 and PC210 Operator's Manual
What are the maximum ambient temperature limits for operating this machine?
The machine must not be operated in areas where the ambient temperature exceeds 40°C.
From: Lincoln Electric INVERTEC PC208 and PC210 Operator's Manual