Key facts
- Brand
- Analog Devices
- Model
- AD623
- Industry
- Industrial
- Documents
- 6
- Languages
- EN
- Last added
- 2012-06-08
Start here

Analog Devices AD623 Instrumentation Amplifier Datasheet
The AD623 is an integrated single supply instrumentation amplifier designed to deliver rail-to-rail output swing on a single supply ranging from +3 V to +12 V. It offers superior user flexibility by allowing single gain set resistor programming, with a gain range from 1 (no resistor) to 1,000. The device holds errors to a minimum by providing superior AC CMRR that increases with increasing gain, making it ideal for rejecting line noise and harmonics up to 200 Hz.
Read onlineAnalog Devices AD623 specifications
| Gain Range | 1 to 1000 |
|---|---|
| Input Offset Voltage (Max) | 200 mV |
| Input Bias Current (Max) | 25 nA |
| Supply Voltage Range (Single) | +3 V to +12 V |
| Bandwidth (G=1) | 800 kHz |
| Settling Time to 0.01% (G=10) | 20 ms |
| Operating Temperature Range | -40 °C to +85 °C |
Source: Analog Devices AD623 Instrumentation Amplifier Datasheet
All Analog Devices AD623 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
- Analog Devices AD623 Instrumentation Amplifier Datasheet 16 p
- Analog Devices AD623 Instrumentation Amplifier Datasheet 24 p
- Analog Devices AD623 Instrumentation Amplifier Datasheet 14 p
- Analog Devices AD623 Instrumentation Amplifier Datasheet 16 p
- Analog Devices AD623 Instrumentation Amplifier Datasheet 16 p
- Analog Devices AD623 Instrumentation Amplifier Datasheet 24 p
Questions answered in these manuals
What is the gain range of the AD623?
The gain can be programmed from 1 to 1,000 using an external resistor, or set to unity gain with no external resistor.
From: Analog Devices AD623 Instrumentation Amplifier Datasheet
Can the AD623 operate on a single supply?
Yes, it is designed for single supply operation from +3 V to +12 V.
From: Analog Devices AD623 Instrumentation Amplifier Datasheet
What is the maximum gain setting for the AD623?
The gain can be programmed up to 1000.
From: Analog Devices AD623 Instrumentation Amplifier Datasheet
What is the typical quiescent current in single‑supply mode?
Typical quiescent current is 305 µA.
From: Analog Devices AD623 Instrumentation Amplifier Datasheet
What is the gain range of the AD623?
The AD623 can be programmed for gains from 1 to 1000.
From: Analog Devices AD623 Instrumentation Amplifier Datasheet
What supply voltage range does the AD623 support for single‑supply operation?
It operates from +3 V up to +12 V on a single supply.