ABB ACS310 Error Codes

93 codes from pages 169–316 of the manual

This is the list of fault, alarm, error codes the ABB manual gives for the ACS310 AC drive. Find your code below and open it for what the manual says about its causes and what to do.

Fault codes from p. 303

CodeWhat it meansPage
2001 OVERCURRENT p. 303
2002 OVERVOLTAGE p. 303
2003 UNDERVOLTAGE p. 303
2004 DIR LOCK p. 303
2005 IO COMM p. 303
2006 AI1 LOSS p. 303
2007 AI2 LOSS p. 303
2008 PANEL LOSS 0308 bit 7 (programmable fault function 3002) p. 304
2009 DEVICE OVERTEMP 0308 bit 8 p. 304
2010 MOTOR TEMP 0308 bit 9 (programmable fault function 3005...3009 / 3503) p. 304
2012 MOTOR STALL 0308 bit 11 (programmable fault function 3010...3012) p. 304
2013 AUTORESET 0308 bit 12 p. 304
2014 AUTOCHANGE 0308 bit 13 p. 304
2015 PFC I LOCK 0308 bit 14 p. 304
2018 PID SLEEP 0309 bit 1 p. 304
5001 Drive is not responding. p. 307
5002 Incompatible communication profile p. 307
5010 Corrupted panel parameter backup file p. 307
5011 Drive is controlled from another source. p. 307
5012 Direction of rotation is locked. p. 307
5013 Panel control is disabled because start inhibit is active. p. 307
5014 Panel control is disabled because of drive fault. p. 307
5015 Panel control is disabled because the local control mode lock is active. p. 307
5018 Parameter default value is not found. p. 307
5019 Writing non-zero parameter value is prohibited. p. 307
5020 Parameter or parameter group does not exist or parameter value is inconsistent. p. 307
5021 Parameter or parameter group is hidden. p. 307
5022 Parameter is write protected. p. 307
5023 Parameter change is not allowed, when drive is running. p. 307
5024 Drive is executing a task. p. 307
5025 Software is being uploaded or downloaded. p. 307
0001 OVERCURRENT (2310) 0305 bit 0 p. 310
0002 DC OVERVOLT (3210) 0305 bit 1 p. 310
0003 DEV OVERTEMP (4210) 0305 bit 2 p. 310
0004 SHORT CIRC (2340) 0305 bit 3 p. 310
0006 DC UNDERVOLT (3220) 0305 bit 5 p. 310
0007 AI1 LOSS (8110) 0305 bit 6 (programmable fault function 3001, 3021) p. 310
0008 AI2 LOSS (8110) 0305 bit 7 (programmable fault function 3001, 3022) p. 310
0018 THERM FAIL (5210) 0306 bit 1 p. 312
0021 CURR MEAS (2211) 0306 bit 4 p. 312
0022 SUPPLY PHASE (3130) 0306 bit 5 p. 312
0024 OVERSPEED (7310) 0306 bit 7 p. 312
0026 DRIVE ID (5400) 0306 bit 9 p. 312
0027 CONFIG FILE (630F) 0306 bit 10 p. 312
0028 SERIAL 1 ERR (7510) 0306 bit 11 (programmable fault function 3018, 3019) p. 312
0029 EFB CON FILE (6306) 0306 bit 12 p. 312
0030 FORCER TRIP (FF90) 0306 bit 13 p. 312
0031 EFB 1 (FF92) 0307 bit 0 p. 313
0032 EFB 2 (FF93) 0307 bit 1 p. 313
0033 EFB 3 (FF94) 0307 bit 2 p. 313
0035 OUTP WIRING (FF95) 0306 bit 15 (programmable fault function 3023) p. 313
0036 INCOMPATIBLE SW (630F) 0307 bit 3 p. 313
0038 USER LOAD CURVE (FF6B) 0307 bit 4 p. 313
0039 UNKNOWN EXTENSION (7086) 0307 bit 5 p. 313
0040 INLET VERY LOW (8A81) 0307 bit 6 p. 313
0041 OUTLET VERY HIGH (8A83) 0307 bit 7 p. 313
0042 INLET LOW (8A80) 0307 bit 8 p. 313
0043 OUTLET HIGH (8A82) 0307 bit 9 p. 314
0101 SERF CORRUPT (FF55) 0307 bit 14 p. 314
0103 SERF MACRO (FF55) 0307 bit 14 p. 314
0201 DSP T1 OVERLOAD (6100) 0307 bit 13 p. 314
0202 DSP T2 OVERLOAD (6100) 0307 bit 13 p. 314
0203 DSP T3 OVERLOAD (6100) 0307 bit 13 p. 314
0204 DSP STACK ERROR (6100) 0307 bit 12 p. 314
0206 CB ID ERROR (5000) 0307 bit 11 p. 314
1000 PAR HZRPM (6320) 0307 bit 15 p. 314
1001 PAR PFC REF NEG (6320) 0307 bit 15 p. 314
1003 PAR AI SCALE (6320) 0307 bit 15 p. 314
1026 PAR USER LOAD C p. 316

Alarm codes from p. 306

Error codes from p. 308

Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with ABB. Found a mistake? Report an error.