Fault code0006
The code means the intermediate circuit DC voltage is not sufficient. The manual's first action is: “Check that undervoltage controller is on (parameter 2006 UNDERVOLT CTRL). Check input power supply and fuses.”
- Model
- ABB ACS310
- Display shows
- DC UNDERVOLT (3220) 0305 bit 5 (0006)
- Type
- Fault code
- Source
- Manual p. 310
What 0006 means
DC UNDERVOLT (3220) 0305 bit 5 p. 310
Common causes
- Intermediate circuit DC voltage is not sufficient due to missing input power line phase, blown fuse, rectifier bridge internal fault or too low input power. p. 310
What to do
- Check that undervoltage controller is on (parameter 2006 UNDERVOLT CTRL). Check input power supply and fuses. p. 310
Before you service the product, read the safety instructions in the manual p. 340.
If 0006 is still not resolved
- contact your local ABB representative or Authorized Service Center for replacement p. 17 “contact your local ABB representative or Authorized Service Center for replacement”