Fault code2008
Code 2008 means the control panel selected as the active control location for the drive has ceased communicating. The manual's first action is: “Check panel connection.”
- Model
- ABB ACS310
- Display shows
- PANEL LOSS 0308 bit 7 (programmable fault function 3002) (2008)
- Type
- Fault code
- Source
- Manual p. 304
What 2008 means
PANEL LOSS 0308 bit 7 (programmable fault function 3002) p. 304
Common causes
- Control panel selected as active control location for drive has ceased communicating. p. 304
What to do
- Check panel connection. p. 304
- Check fault function parameters. p. 304
- Check control panel connector. p. 304
- Refit control panel in mounting platform. p. 304
- If drive is in external control mode (REM) and is set to accept start/stop, direction commands or references through control panel: Check group 10 START/STOP/DIR and 11 REFERENCE SELECT settings. p. 304
Before you service the product, read the safety instructions in the manual p. 340.
If 2008 is still not resolved
- contact your local ABB representative or Authorized Service Center for replacement p. 17 “contact your local ABB representative or Authorized Service Center for replacement”
This page summarises what the manufacturer’s manual says about 2008; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.