ABB ACS310 Error 2006: AI1 LOSS

AC drive · taken from the manufacturer’s manual, pages cited

Fault code2006

Code 2006 means the analog input AI1 signal has fallen below the limit defined by parameter 3021 AI1 FAULT LIMIT. The manual's first action is: “Check fault function parameter settings.”

Model
ABB ACS310
Display shows
AI1 LOSS (2006)
Type
Fault code
Source
Manual p. 303

What 2006 means

AI1 LOSS p. 303

Common causes

  • Analog input AI1 signal has fallen below limit defined by parameter 3021 AI1 FAULT LIMIT. p. 303

What to do

  1. Check fault function parameter settings. p. 303
  2. Check for proper analog control signal levels. p. 303
  3. Check connections. p. 303

Before you service the product, read the safety instructions in the manual p. 340.

If 2006 is still not resolved

  • contact your local ABB representative or Authorized Service Center for replacement p. 17
    “contact your local ABB representative or Authorized Service Center for replacement”