Fault code5011
5011 on the ABB ACS310 is listed in the manual as: Drive is controlled from another source.. The manual's first action is: “Change drive control to the local control mode.”
- Model
- ABB ACS310
- Display shows
- Drive is controlled from another source. (5011)
- Type
- Fault code
- Source
- Manual p. 307
What 5011 means
Drive is controlled from another source. p. 307
Common causes
- Drive is controlled from another source. p. 307
What to do
- Change drive control to the local control mode. p. 307
Before you service the product, read the safety instructions in the manual p. 340.
If 5011 is still not resolved
- contact your local ABB representative or Authorized Service Center for replacement p. 17 “contact your local ABB representative or Authorized Service Center for replacement”
This page summarises what the manufacturer’s manual says about 5011; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.