ABB ACS310 Error 2009: DEVICE OVERTEMP 0308 bit 8

AC drive · taken from the manufacturer’s manual, pages cited

Fault code2009

Code 2009 means the drive IGBT temperature is excessive, with an alarm limit of 120 °C. The manual's first action is: “Check ambient conditions. See also section Derating on page 327.”

Model
ABB ACS310
Display shows
DEVICE OVERTEMP 0308 bit 8 (2009)
Type
Fault code
Source
Manual p. 304

What 2009 means

DEVICE OVERTEMP 0308 bit 8 p. 304

Common causes

  • Drive IGBT temperature is excessive. Alarm limit is 120 °C. p. 304

What to do

  1. Check ambient conditions. See also section Derating on page 327. p. 304
  2. Check air flow and fan operation. p. 304
  3. Check motor power against drive power. p. 304

Before you service the product, read the safety instructions in the manual p. 340.

If 2009 is still not resolved

  • contact your local ABB representative or Authorized Service Center for replacement p. 17
    “contact your local ABB representative or Authorized Service Center for replacement”

This page summarises what the manufacturer’s manual says about 2009; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.