Agilent manuals, page 166
Analysis of Aromatic Amines in Leather Extracts by CE-MS Application Note
Application Note 2 pages · 162 KB · ENThis application note describes the analysis of aromatic amines in leather extracts using Capillary Electrophoresis with Mass Spectrometry detection.
Agilent Analysis of Hallucinogenic Mushrooms by CE-ESI-MS Application Note
Application Note 2 pages · 97 KB · ENThis application note demonstrates the feasibility of analyzing hallucinogenic mushrooms using Agilent Capillary Electrophoresis coupled with Electrospray…
Analysis of Drugs of Abuse by CE-ESI-MS Application Note
Application Note 2 pages · 93 KB · ENThis application note demonstrates the feasibility of analyzing drug substances like LSD and mixtures containing methamphetamine, cocaine, and heroin using…
Agilent 5990-3395EN Optimized parameters for the analysis of tropane alkaloids by CE-ESI-MS Application Note
Application Note 2 pages · 88 KB · ENThis application note details optimized parameters for analyzing tropane alkaloids in Datura seeds using Agilent Capillary Electrophoresis coupled with ESI-MS.
Agilent Quantification of Alkaloids Berberine Palmatine Jatrorrhizine Application Note
Application Note 2 pages · 105 KB · ENThis application note describes the quantitation of alkaloids berberine, palmatine, and jatrorrhizine in Mahonia stem using capillary electrophoresis.
Agilent J&W DB-5ms Ultra Inert Column Application Note
Application Note 8 pages · 232 KB · ENThis application note compares the inertness of Agilent J&W DB-5ms Ultra Inert GC columns against competitors using active basic compounds, acids, and…
Agilent ChemStation B.04.01 Compliance with 21 CFR Part 11 Technical Note
Other 12 pages · 60 KB · ENThis technical note describes how Agilent ChemStation and OpenLAB ECM integration ensures compliance with US Federal guidelines for electronic records.
Agilent ZORBAX Eclipse Plus C18 Improved Simvastatin Analysis Application Note
Application Note 12 pages · 536 KB · ENThis application note describes method adjustments for Simvastatin analysis using shorter Agilent ZORBAX Eclipse Plus C18 columns to save time and solvent.
Agilent Capillary Zone Electrophoresis of Neuropeptides Application Note
Application Note 2 pages · 103 KB · ENThis application note describes the separation and determination of neuropeptide diastereomers using Agilent capillary electrophoresis with diode-array…
Agilent Peptide Mapping Analysis Using Capillary Electrophoresis Application Note
Application Note 4 pages · 314 KB · ENThis application note describes peptide mapping and analysis using capillary electrophoresis (CE) as a complementary tool to HPLC for protein identification…
Agilent Lipidomics Discovery Profiling Targeted LC/MS Analysis in 3T3-L1 Differentiating Adipocytes Application Note
Application Note 8 pages · 801 KB · ENThis application note describes the use of Agilent 1200 Series LC and 6520 Q-TOF for lipidomics discovery profiling and targeted analysis in differentiating…
Agilent StableBond SB-Aq Salicylic Acid Impurities Application Note
Application Note 4 pages · 184 KB · ENThis application note demonstrates the separation of salicylic acid impurities using different acid mobile-phase modifiers with Agilent StableBond SB-Aq…
Agilent Capillary Electrophoresis System Chiral Analysis Application Note
Application Note 20 pages · 2 MB · ENThis application note provides strategies and examples for chiral analysis using the Agilent Capillary Electrophoresis System with cyclodextrins.
Agilent 7890A/NPD/5975C/DRS GC/MSD System Application Brief
Application Note 4 pages · 204 KB · ENThis application brief describes a rapid forensic toxicology screening method using an Agilent 7890A GC with NPD and 5975C MSD, achieving 85% time savings.
Agilent 1200 Series RRLC and 6410B LC/MS Application Note for Impurity D Quantification
Application Note 8 pages · 450 KB · ENThis application note describes a UV and MS detector chromatographic method for quantifying genotoxic Impurity D in Atenolol using Agilent 1200 Series RRLC…